TM2 X R MINI
34
A4518_6H82_Rev.A
SPECIAL FUNCTIONS
SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily, for example,
with the purpose of setting the limit switches during assembly in the factory. A later
final saving of the remote control will be possible using the appropriate command
sequence (see: “SETTING THE FIRST REMOTE CONTROL”). The operations described
below can be carried out only when the control unit has just come out of the factory
or after a full memory clearing (see: “FULL MEMORY CLEARING”). The control unit
makes the following operations possible only within the time limits described in
order to make sure that the short-term setting is used only in the installation or
factory setting phase and not during daily use. Power up the control unit, make
sure that no other control units having an empty memory are powered up in the
same operating range.
Within 30 seconds after start
, press the B and C buttons simultaneously until the
motor gives a confirmation signal.
The remote control will remain stored for 5 minutes
, while the control unit is powe-
red up. After 5 minutes or when the control unit has its power cut off, the remote
control will be cancelled.
T1: First remote control to be set
T1
+
B
C