background image

12

1

1

1

2
3

1
2

3

1

1

1

1

1

1

1

1

2

1

1

1

1

No blue LED

There is no power.

The polarity of the power 

supply is inverted.

Check cable and connexion.

Check the polarity of the power supply.

All LEDs have been de-

activated by remote control.

Activate the LEDs by remote control.

TROUBLESHOOTING

The detection LED 

remains green.

The orange LED is 

flashing and the 

detection LEDs are 

red. 

The detection LED 

remains red.

The orange LED 
is on.

The sensor does 

not respond to the 

remote control.

The sensor does not 

unlock.

The detection field is too 

small or deactivated.

Someone or something is 

in the detection field.

The field is touching the 

floor, the wall or the barrier, 

which leads to detection.

No background (reference 

point) is found.

The sensor is masked.

The power supply voltage 

is exceeding the acceptable 

limits.

The sensor exceeds its 

temperature limits.

Internal error

The batteries in the remote 

control are not installed 

properly or dead.

The remote control is badly 

pointed. 

A reflective object is in close 

proximity to the sensor.

You have to enter an access 

code or the wrong code was 

entered. 

The object size is too small.

Check the size of the fields.
Launch a teach-in.

Step out of the field and/or remove the any 

object(s) from the field.

Activate the 3 red beams and check if the 

position of the sensor is correct. 

If not, adjust the hex screws.
Verify the field size.
Launch a teach-in.

Check the position of the sensor.

Check the mounting side setting.

If no reference point is found, set the mounting 

side to value 3 or 4.

Launch a new teach-in.

Verify and clean the front screens 

with a damp cloth.

Check the power supply voltage.

Verify the outside temperature where the sensor 

is installed. Eventually protect the sensor from 

sunlight using a cover.

Wait a few seconds. 

If the LED remains ON, reset the power supply. 

If the LED turns on again, replace the sensor.

Verify or replace the batteries.

Point the remote control towards the sensor, 

but with a slight angle. The RC should not be 

pointed in a right angle in front of the sensor.

Avoid highly reflective material in proximity to 

the sensor.

Cut and restore power supply. 

No code is required to unlock during the first 

minute after powering.

Decrease the min. object size.

Summary of Contents for XGUARD-5H

Page 1: ...1 XGUARD 5H EN LASER SCANNER FOR BARRIERS GATES User s Guidefor product version 0100 and more with max detection range of 5 0 m x 6 5 m...

Page 2: ...n and damp cloth Do not use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning Do not look into the laser emitter or the visible red laser beams The warrant...

Page 3: ...osition lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 1 Detection LED relay 1 opening field 2 Detection LED relay 2 safety field...

Page 4: ...ontrol If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits X NUMBER OF FLASHES VALUE OF THE PARAMETER field width 4 2 m field width is defined by teach i...

Page 5: ...order to avoid vibrations Close the protection cover and fasten it firmly Turn the sensor until the two triangles are face to face Position the housing on the bracket Open the protection cover plug th...

Page 6: ...e sequence After 15 minutes the beams switch off Verify the lateral position of the sensor Make sure the laser beam is visible on the opposite pole Verify if both beams are on equal height No test fun...

Page 7: ...NT surface of min 15 cm WITHOUT REFERENCE POINT left right The sensor will automatically adjust the safety field on the basis of the reference point if C 00 OR Choose the correct mounting side LEFT or...

Page 8: ...Once the sensor has finished the teach in make sure that the safety field is correctly configured and that the area around the barrier or gate is safe The safety field can be adapted more precisely b...

Page 9: ...ne If you walk along the detection area while the teach in function is active the sensor memorizes the outline of the walkpath and stores this as a new detection field The shortest distance measured b...

Page 10: ...hing and going away 400 CENTER unidirectional detection only approaching in any direction 200 CENTER unidirectional detection only approaching towards the barrier gate 100 CENTER unidirectional detect...

Page 11: ...ive P passive REMOTE CONTROL ADJUSTMENTS OPTIONAL DETECTION DELAY approximate values SAFETY FIELD REDIRECTION RELAY 1 RELAY 2 off presence presence presence motion motion or presence motion presence o...

Page 12: ...roximity to the sensor You have to enter an access code or the wrong code was entered The object size is too small Check the size of the fields Launch a teach in Step out of the field and or remove th...

Page 13: ...t screens Norm conformity laser scanner time of flight measurement motion and presence 5 0 m x 6 5 m 2 0 3516 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW powe...

Page 14: ...14...

Page 15: ...15...

Page 16: ...PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING BEA hereby declares that the XGUARD 5H is in conformity with the basic requirements and the other relevant provisions of the directives 2014 3...

Reviews: