XKPR 13
532192 - Rev.C
5
5
1. INSTALLATION
!
The support surface must be flat and smooth. The IP sealing gaskets must be present and intact
in the base (
1
) and in the body (
5
).
1.
Prepare the connecting cables and install the base. Follow the instructions given in
1
.
2.
Connect the XKPR to the SPINet terminals of the Door Controller board. Follow the instructions given
in
2
and
3
.
-
Remove at least 1 cm of the conducting sheath.
-
Wires having a maximum section of 0.5mm
2
can be placed in the connector on the XKPR
3.
Configure the jumper according to the type of reader, A or B. (
4
).
4.
Turn power on to the board:
-
The XKPR keypad lights up after a few seconds.
5.
Make sure that the keypad and the proximity sensor are working correctly.
6.
Fasten the body to the base (
5
). Install the cover (
6
).
EN
Translation of the original instructions