XKPR 15
532192 - Rev.C
MAINTENANCE
Clean the outer surfaces only with a soft cloth Do not use detergents or oils. Do not make any modifications
to the original components. Only use original FAAC spare parts.
4. CONNECTING TO THE BOARD WITH SPINET
-
Connect the Spinet Bus to terminal J1 as indicated in
3 .
!
For each device connected to the SPINet line, position the address Pins so that the same address
is used on only one device.
5. TROUBLESHOOTING
Indication
Explanation
Necessary action
The XKPR gives an error when it is
switched on.
There are two readers with the
same address.
Change the address for one of the
two devices.
No LEDs (Red or Green) are activa-
ted when a code is entered.
The keypad is disabled.
Check the keypad configuration of
the Device in the Keydom software.
The device does not turn on.
No power or device not working. Check that the power supply is
connected and live. If there are no
errors, replace the device.
An enabled user code or the tran-
sponder has not been validated,
the red LED lights up.
Software configuration error.
Check the Access Media configura-
tion in Keydom.
EN
Translation of the original instructions