INSTRUCTION BOOKL: PELLET STOVE FOR LOCAL AIR HEATING .
DESIGN INNOVATION SUSTAINABILITY FUNCTIONALITY HIGH PERFORMANCE
55/80
Message
Meaning
Solutions
ER01
OR
ERO2
Excess temperature in the
pellet tank
(If the temperature of the
pellet tank reaches the limit
set by the manufacturer, the
equipment goes into
extinguishing mode)
1-
Let it cool down and turn on again.
2-
If the error persists, consult technical
support.
ER03
Firing extinguished by a
drop in temperature
(If in the ignition phase the
combustion temperature
drops, the stove goes into
extinguishing mode;
If during operation the
temperature of the
smoke/gas reaches a value
below the set limit, the stove
goes into extinguishing mode)
1-
Check that the removable accessories are
correctly positioned (page 64);
2-
Can the pellets reach the burner? Check that
there is fuel in the pellet tank.
If yes:
pre-load following the instructions in
LoAd Function (page 29) before starting the
stove. The worm may be empty.
Errors
FOR
SAFETY'S
SAKE,
THE
SYSTEM
CLOSED
THE
BURNER
BY
BLOCKING
THE
STOVE!
Press the P1 button
, until you hear
a "bip" sound.
Note!
For safety, the stove will only
allow the unlocking and
removal of the error after the
OFF
process
has
been
completed.
How do I eliminate Errors?
P1