Version 05/06 - Page 4

1.

  Remove  the  cover  from  the  remote  blower.  Then  remove  the 

wiring box cover.

2.

  Pull  electrical  wiring  through  the  hole  in  the  blower  base  and 

secure it according to local codes.

3.

 Make the electrical connections. Connect the white and black 

wires of the power supply cable wire to the white and black wires 

in the wiring box with twist-on connector. Connect the green power 
supply ground wire to the green ground screw.

4. 

Replace the wiring box cover and screws taking care not to pinch 

the wiring under the wiring box cover.

5.

 Turn on power (See Installation Instructions that came with your 

vent hood system). Check operation of blower and make sure damper 

is opening freely.

6.

 Reinstall remote blower housing.

Flat roof installations

Make the duct & electrical connections

wiring diagram

You can be killed or seriously injured if you don’t follow 

instructions.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

• Disconnect power before making electrical connection.

• Connect the ground wire to green ground screw in wiring box.

Failure to do so can result in death or electrical shock.

   WARNING

Figure 3 - Flat roof installations

1.

 Locate the 11" (27.9 cm) dia. hole between rafters.

2.

 Build a sloping base that will mount the remote blower at a 

minimum pitch of 2-1/2" (6.4 cm). 

3.

 Weatherproof the base as required.

4.

 Locate the base so that the remote blower’s vent aligns with the 

11" (27.9 cm) dia. hole and the blower sits evenly on the base with 
no gaps. Note: Make sure that the discharge end of the remote 
blower faces away from the direction of prevailing winds.

5.

 Use dimensions from either 

FIGURE 1 or 2

 to locate the 1-1/4" 

(3.0 cm) dia. wiring hole.  CONTINUE WITH POINT 

6

 UNDER 

ROOF INSTALLATIONS ON PAGE 3.

Figure 4 - Electrical connections

!

Warranty  &  Service

All Faber products are warranteed against any defect in materials or work-

manship for the original purchaser for a period of 1 year from the date of 

original purchase.  This warranty covers labor and replacement parts.  The 

warranty does not cover consumable parts such as filters and light bulbs.  

This warranty does not apply if this product has been subjected to faulty 

installation, misuse, or neglect.  This warranty excludes any consequential 

expense or damage resulting from any use or malfunction of the product.  

All implied warranties are limited to the duration of this warranty. 

To obtain warranty service, contact the dealer from whom you purchased 

the rangehood, or the local Faber distributor.  If you cannot identify a local 

Faber distributor, contact us at (508) 358-5353 for the name of a distributor 

in your area.

Summary of Contents for 1200 CFM

Page 1: ...le Wire sizes must conform to the requirements of the National Electrical CodeANSI NFPA70 latestedition orCanadianElectricalCode C22 1 and C22 2 No 113 M1984 or latest edition and all local codes and ordinances 14 gauge wire minimum is recommended Remote Blower 1200 CFM Installation Instructions Use Care Manual You can be killed or seriously injured if you don t follow instructions TO REDUCE THE R...

Page 2: ...performance Where possible remote blower should be centered between wall studs or roof rafters The size of the duct system should be uniform Do not install two elbows together Useducttapetosealalljointsintheductsystem Usecaulkingto sealremotewallorflooropeningaroundthecap Flexibleduct is not recommended It creates back pressure air turbulence and greatly reduces performance Make sure there is prope...

Page 3: ...r slope of roof that minimizes vent run Avoid obstacles such as TV leads electric lines etc If remote blower top is level with roof peak it will not be seen from street Remember this location as you work from inside the attic 2 Mark a point half way between the rafters and drill a guide hole at this point 3 From the outside using the guide hole as a starting point mark the rectangular cut out as i...

Page 4: ... 9 cm dia hole between rafters 2 Build a sloping base that will mount the remote blower at a minimum pitch of 2 1 2 6 4 cm 3 Weatherproof the base as required 4 Locatethebasesothattheremoteblower sventalignswiththe 11 27 9cm dia holeandtheblowersitsevenlyonthebasewith no gaps Note Make sure that the discharge end of the remote blower faces away from the direction of prevailing winds 5 Usedimension...

Page 5: ...le bas ou la hotte Utiliser du câble flexible blindé ou à gaine non métallique Un serre câble homologation UL CSA doit être installé à chaque extrémité du câble d alimentation La taille des conducteurs doit satisfaire les prescriptions de la plus récente édition du Code national de l électricité ANSI NFPA 70 ou des normes CSA C22 1 94 Code canadien de l électricité C22 1 et C22 2 N 0 113 MI984 ou l...

Page 6: ... placer tout raccord de transition nécessaire aussi près que possible de la hotte ou du système d aspiration par le bas utilisé e en conjonction avec ce ventilateur Ce ventilateur extérieur devra être alimenté par un câble électrique homologation UL CSA indépendant installé en même temps que le circuit d évacuation Longueur maximale du circuit d évacuation 55 pi pour Dia 10 po conduit d évacuation...

Page 7: ...r un endroit sur le versant arrière du toit qui minimisera la longueur du conduit d évacuation Éviter tout obstacle comme câble de télévision conducteur électrique etc Si le sommet du ventilateur extérieur est au même niveau que le faîte du toit il ne sera pas visible depuis la rue tenir compte de ceci lors des opérations effectuées dans le grenier 2 Marquer un point centré entre les solives pour ...

Page 8: ... Respecter les dimensions mentionnées à la FIGURE 1 ou 2 à la page 3 pour positionner le trou de 3 cm 1 1 4 po pour le passage du câblage diagramme de câblage Figure 3 sur un toit plat Pour l installation du ventilateur extérieur sur un toit plat Risque possible de décès ou de blessure grave si vous ne suivez pas le instructions AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC ÉLECTRIQUE O...

Reviews: