Version 07/11 - Page 6
PREPARE THE WALL
1.
Disconnect and move freestanding range from cabinet
opening to provide easier access to upper cabinet and rear
wall. Put a thick, protective covering over cooktop, set-in
range or countertop to protect from damage or dirt.
2.
Determine and clearly mark with a pencil the center line
on the wall where the rangehood will be installed.
3.
The canopy attaches to the wall by two mounting brackets
(Item 1 in FIGURE 5)
. The canopy of the rangehood hangs
on the two brackets which must be mounted with the flanges
on the top of the bracket and pointing away from the wall.
Before installing the brackets, the adjustment screws must be
installed into the bottom of the bracket. These two screws are
provided in the hardware package and have hexagon heads
with a slot for a flat blade screwdriver. The dimensions illustrate
mounting the canopy 24" above the cooking surface.
If a
Backsplash
is to be used with this rangehood, it must be
installed before the rangehood. Installation instructions for
the
Backsplash
are supplied in its box. The height of the
Backsplash
will determine the bottom edge of the canopy.
6.
Determine the proper location for the Power Supply Cable
(FIGURE 6)
. Use a 1 1/4" Drill Bit to make this hole. Run the
Power Supply Cable. Use caulking to seal around the hole.
DO NOT turn on the power until installation is complete.
FIGURE 7
INSTALL THE RANGEHOOD
1.
Remove the unit from the carton and place on a flat sur-
face for assembly. Cover the surface to prevent accidental
damage. Remove all parts including the mounting hardware
before discarding the carton.
2.
Remove the grease filters from the unit and set aside.
The grease filters are removed by pressing the handle in
front of the filter
(FIGURE 7)
. When replacing, make sure
that the filters are properly positioned with the handles in
front and visible.
FIGURE 5
4.
The chimney mounts by two brackets
(Item 2 in FIGURE
5)
. Note the position of the brackets. The top bracket should
be installed about 1/8" away from the ceiling. The bottom
bracket must be installed at the bottom point of the upper
chimney sleeve.
Determine the proper location for each bracket and install the
brackets on the wall.
MAKE SURE THAT THE BRACKETS
ARE SECURELY FASTENED TO THE WALL.
5.
Determine and make all necessary cuts in the wall for the
ductwork. Install the ductwork before the rangehood.
3.
Remove the cover from the field wiring compartment.
Remove the wiring electrical knockout using a flat-blade
screwdriver. Feed the Power Supply Cable through the
electrical knockout.
FIGURE 6
30 MODELS
36 MODELS
4.
Hang the canopy on the
brackets as indicated in
FIGURE 8
. There are two
rectangular holes on the rear
of the canopy. The brackets
pass through these holes
and the canopy hangs from
the flanges on the brackets.
Due to the weight of the
canopy, two people should
lift it to avoid injuries. Make
sure that the canopy is se-
cure on the brackets before
releasing.
FIGURE 8