Version Hi-Lo 02/04 - Page 5

TOOLS  NEEDED  FOR  INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1  1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape

PARTS  SUPPLIED  FOR  INSTALLATION
• 1 Backdraft Damper
• 1 Vent Grate (for recirculating installations only)
• 1 Literature Package

PARTS  NEEDED  FOR  INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork

OPTIONAL ACCESSORIES AVAILABLE
• Charcoal Filters
For recirculating installations only,
replace charcoal filters as needed
part # 6093034

The Inca HC power pack rangehood is designed to offer a wide flexibility of
installations.  The rangehood can be ducted vertically (FIGURE 2) or horizontally
(FIGURE 3) through a 6" round vent.  The unit can also be installed in a recirculating
configuration (FIGURE 4).  The unit comes standard in top venting position.

45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap

FIGURE  A

9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap

Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE  B

3.0 feet
5.0 feet

12.0 feet

0.0 feet

HORIZONTAL  DUCTING

FIGURE  2

VERTICAL

DUCTING

For direct rear venting, you must change the blower position.  Remove the 2 black
screws from the control panel (A in FIGURE 2).  This allows the control panel to
slide through its housing, providing the necessary wire slack needed to rotate the
blower housing.  Remove the 12 screws that hold the metal housing to the
rangehood body.  Remove the 4 screws that hold the blower housing to the metal
housing.  Rotate the blower 90 degrees toward the back and then flip it over 180
degrees.  Be sure that the power supply cable is properly positioned in the nearest
hole.  Replace all screws, making sure that they are firmly fastened.  Reinstall control
panel.

FIGURE  3

RECIRCULATING  INSTALLATIONS

For recirculating installations (FIGURE 4),  Charcoal Filters    are  necessary.
Remove all three grease filters and set aside.  Attach one charcoal filter to each end
of the blower.  Each charcoal filter attaches to the black grid on the side of the blower.
Rotate the filter clockwise to install and counterclockwise to remove (FIGURE 4A).
Replace all three grease filters.  Recirculating installations also require some duct
work to divert the air out of the cabinet.  The duct work must not terminate inside
the cabinet.  The plastic vent grate supplied with the rangehood (FIGURE 4B)
can be used to cover the duct opening.

PLAN YOUR DUCTWORK

The Inca HC requires 6" round
ductwork.  To ensure that the blower
performs to its highest possible capac-
ity, ductwork should be as short and
straight as possilbe.

The ductrun should not exceed 35 feet if
ducted with the required minimum of 6"
round duct.  Calculate the length of the
ductwork by adding the equivalent feet in
FIGURE A for each piece of duct in the
system  An example is given in FIGURE B.

For best results, use no more than three
90

°

    elbows.  Make sure that there is a

minimum of 24" of straight duct between
elbows if more than one is used.  Do not
install two elbows together.

6” round

duct

ceiling

hood

1234567890

1234567890

1234567890

vent grate

cabinet

ceiling

soffit

vent grate

cabinet

6” round

duct

123

123

123

123

123

123

123

123

123

123

FIGURE 4A

FIGURE 4B

FIGURE 4

hood