Installation manual Aspect Premium ST L,XL

 

 

10 < 

<

 

<

 

We advise using a gas connection directly from the 
gas meter to the appliance, with a shut-off valve in 
the proximity of the appliance, which must always 
be freely accessible. Position the gas connection so 
that it is easily accessible for service and the 
burner unit can be disassembled at any time. 
 

4.2

 

Electrical connection 

Install a 230VAC/50Hz wall socket near the 
fireplace for connecting the control unit. 
 
See fig. 2.8a for the wiring diagram: 

A = adapter (6 V) 
B = Gasvalve 
C = Receiver 
D = Ignition pin 

 
See fig. 2.8b for the wiring diagram with I.T.C 
(optional). 

A = adapter (6 V) 
B = Gasvalve 
C = Receiver 
D = Ignition pin 
E = I.T.C. 

 

4.3

 

Smart Home installation 

 

 

Please note 

This is only possible if the fire is equipped 
with I.T.C!  

 
The controller can be connected to an external 
source, such as a Domotica system, by using a 
Faber Interface Unit (article number A9323000). 
 

4.4

 

Preparing the fireplace 

 

Remove the fireplace from its packaging. 
Ensure that the gas supply pipes under 
the appliance are not damaged. 

 

Remove the glass and any mouldings, 
store them at a safe place and remove the 
packaged parts from the fireplace. 

 

Prepare the gas connection on the 
regulator. 

 

4.5

 

Positioning the fireplace 

Take into account the installation requirements 
(see chapter 3). Place the fireplace at the right 
place and level it. 
Rough height adjustment: 

 

With the adjustable (optional) legs. 

Accurate height adjustment:  

 

With the adjustable feet. 

 
 
 
 

4.6

 

Mounting flue gas exhaust materials 

Assemble the flue gas exhaust materials according 
to the installation manual supplied with the flue 
gas exhaust material (40011968)! 

 

The distance to combustible materials 
must be min. 50mm, calculated from 
outside of the flue material. 

 

Never start immediately with length-
adjustable concentric flue material on the 
appliance. 

 

Horizontal sections should be installed to 
allow a slope towards the fireplace  

(3 degrees). 

 

Build the system from the fireplace. If this 
is not possible you can make use of an 
extendable adapter section. 

 

For fitting of the flue system, the 0,5m 
length-adjustable pipe must be used. 
Make sure that the inner pipe is always 
15mm longer than the outer pipe. Wall- 
and roof terminal can also be cut. These 
components must be secured with a self-
tapping screw. 

 

4.7

 

Constructing the false chimney 

Before positioning the false chimney, we advise to 
perform a functional test with the fireplace as 
defined in chapter 7 “Checking the installation”. 
 

False chimney 

 

Construct the false chimney of non-
combustible material in combination with 
metal profiles or of masonry/concrete 
blocks. 

 

Always use a lintel or reinforcing bars 
while bricking the false chimney. They 
should not be placed directly on the 
fireplace. 

 

Make sure that the fireplace never 
functions as a load-bearing construction, 
because of the expansion of the fireplace 
through warmth. 

 

Ventilation 

Correct ventilation prevents damaging overheating 
of the gas control block and its electronics and also 
limits the temperature of the convection air. Use 
the supplied Faber ventilation grids (article number 
A9296400) or a similar alternative with a minimum 
free passage of 200cm² per grid, in the space 
above the fire, when building the false chimney. 
Within the false chimney, an horizontal screen 
plate, made of non-combustible material, must be 
installed just above the ventilation openings. (see 
“A” in fig. 1.0 or 1.2). 

 
 

Summary of Contents for Aspect Premium RD L

Page 1: ...Installation manual Aspect Premium ST L Aspect Premium ST XL ENG 40010936 2016 ...

Page 2: ...Installation manual Aspect Premium ST L XL 1 ...

Page 3: ...Installation manual Aspect Premium ST L XL 2 ...

Page 4: ...Installation manual Aspect Premium ST L XL 3 1 0 1 1 1 2 1 3 1 4 1 5 ...

Page 5: ...Installation manual Aspect Premium ST L XL 4 1 6 1 7 1 8 2 0 2 1 2 2 2 3 X Y ...

Page 6: ...Installation manual Aspect Premium ST L XL 5 2 4 2 5 2 6 2 7 2 8a ...

Page 7: ...Installation manual Aspect Premium ST L XL 6 2 8b ...

Page 8: ...Installation manual Aspect Premium ST L XL 7 ...

Page 9: ...ns Please note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficien...

Page 10: ... the desired outlet meets the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and balconies Roof edges with the exception of the ridge edge see chapter 15 C11 outlet via facade Through a wall or façade use a Faber wall outlet Depending on the flue calculation this can...

Page 11: ... the flue gas exhaust material 40011968 The distance to combustible materials must be min 50mm calculated from outside of the flue material Never start immediately with length adjustable concentric flue material on the appliance Horizontal sections should be installed to allow a slope towards the fireplace 3 degrees Build the system from the fireplace If this is not possible you can make use of an...

Page 12: ...w fiber Glow fiber gives a decorative glow effect Pull the glow fiber apart and spread it between the logs on the burner Please note Keep the pilot flame free from glow fiber Start the fireplace as described in the user manual Assess if the flame distribution is good Move or remove any chips Install the front glass and check the fire image 6 2 Pebbles Grey stones See the supplied decoration instru...

Page 13: ...n the built in frame and the front glass fig 1 6 X measuring pipe air supply Y measuring pipe flue gas The ratio CO2 and CO must not be greater than 1 100 Example CO2 is 4 and CO is 400ppm measured at the highest point If the ratio is greater than 1 100 or flue gases are measured in the air supply check the points in section 7 1 8 Instructions for client Recommend that the fire should be checked a...

Page 14: ...ation in the drawings fig 12 1 12 2 and 12 3 Total Horizontal Length THL THL is the Total Horizontal Length and consists of elbows and pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are...

Page 15: ...20 x x x x x x x 11 80 20 50 20 30 20 30 20 x x x x x x x 12 80 20 50 20 30 20 30 20 x x x x x x x 13 80 20 50 20 40 20 30 20 x x x x x x x 14 80 20 50 20 40 20 30 20 x x x x x x x 15 80 20 50 20 40 20 30 20 x x x x x x x 16 80 20 50 20 40 20 30 20 x x x x x x x 17 80 20 50 20 40 20 30 20 x x x x x x x 18 80 20 50 20 40 20 30 20 x x x x x x x 19 80 20 50 20 40 20 30 20 x x x x x x x 20 80 20 50 20...

Page 16: ...0 4 80 4 80 4 75 4 70 4 65 4 65 4 60 4 50 4 50 4 40 4 11 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 50 4 40 4 12 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 13 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 14 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 15 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 16 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 ...

Page 17: ...40 20 x x x x x x x 11 50 20 60 20 50 20 50 20 x x x x x x x 12 60 20 70 20 60 20 60 20 x x x x x x x 13 70 20 80 20 70 20 70 20 x x x x x x x 14 80 20 80 20 80 20 80 20 x x x x x x x 15 80 20 80 20 80 20 80 20 x x x x x x x 16 80 20 80 20 80 20 80 20 x x x x x x x 17 80 20 80 20 80 20 80 20 x x x x x x x 18 80 20 80 20 80 20 80 20 x x x x x x x 19 80 20 80 20 80 20 80 20 x x x x x x x 20 80 20 80...

Page 18: ...70 4 70 4 60 4 50 4 50 4 40 4 30 4 x x x 11 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 12 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 13 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 14 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 15 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 16 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 17 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 18 80 4 80 4 70 ...

Page 19: ...Installation manual Aspect Premium ST L XL 18 12 Examples flue materials ...

Page 20: ... 1 5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizo...

Page 21: ...he installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In ca...

Page 22: ... efficiency index EEI 81 81 81 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day time switch With opti...

Page 23: ...nergy efficiency index EEI 83 83 83 Type heating output control room temperature no no no no yes no Diameter outlet inlet 130 200 Technical data Type indication s Aspect Premium RD XL Aspect Premium ST XL Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW ...

Page 24: ...Position outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Sho...

Page 25: ...Installation manual Aspect Premium ST L XL 24 16 Troubleshooting guide ...

Page 26: ...Installation manual Aspect Premium ST L XL 25 ...

Page 27: ...Installation manual Aspect Premium ST L XL 26 17 Dimensional drawings 17 1 Aspect Premium ST L ...

Page 28: ...Installation manual Aspect Premium ST L XL 27 17 2 Aspect Premium ST XL ...

Page 29: ...Installation manual Aspect Premium ST L XL 28 17 3 Remote access door article number A9299463 ...

Page 30: ...Installation manual Aspect Premium ST L XL 29 17 4 Ventilation grid article number A9296400 ...

Page 31: ...Installation manual Aspect Premium ST L XL 30 17 5 Adjustable feet article number A9319696 ...

Page 32: ...Installation manual Aspect Premium ST L XL 31 18 Decoration instruction card 18 1 Log set Aspect Premium ST L ...

Page 33: ...Installation manual Aspect Premium ST L XL 32 18 2 Log set Aspect Premium ST XL ...

Page 34: ...Installation manual Aspect Premium ST L XL 33 18 3 Pebbles 18 4 Grey stones ...

Page 35: ......

Page 36: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: