background image

 

Installation manual Aspect Premium ST L,XL

 

 

11 < 

<

 

<

 

Installation and finishing 

 

 

Please note! 

 

Take into account a minimum distance of 
2mm due to expansion of the fireplace. 

 

Take into account the thickness of any 
finishing layer! 

 

5

 

Removing glass 

 

Remove the cover strips on both sides. 
(see fig. 2.0); 

 

Remove the cover strip on the bottom. 
(see fig. 2.1); 

 

Place the suction cups on the glass (see 
fig. 1.8); 

 

Remove the sealing cord (see fig. 2.2); 

 

Remove the glass cord lists on both sides. 
(see fig. 2.3); 

 

Slide the glass upwards to release the 
lower edge from the slot. Now move the 
lower edge of the glass forward and lower 
the glass into the opening between the 
inner frame and the appliance. (see fig. 
2.4 and 2.5). 

 

Pull the top of the glass towards to you 
and lift up to remove. (see fig. 2.6). 

 
For replacing the glass repeat the steps in reverse 
order. 

 

 

Please note! 

Avoid fingerprints on the glass, these are no 
longer removable once the fire is used. 
 

6

 

Placing decoration material 

 

 

Please note! 

 

It is not permitted to use other or to add 
more material in the combustion 
chamber. 

 

Do not throw the decoration material on 
the burner at once. it is possible that the 
burner gets clogged. 

 

6.1

 

Log set 

See the supplied decoration instruction card or 
chapter 18.1 or18.2: 
 

 

Place the log set. 

 

Distribute the black and grey chips around 
the burner. 

 

Keep the pilot flame free from chips. 
 

Glow fiber 

Glow fiber gives a decorative glow effect. Pull the 
glow fiber apart and spread it between the logs on 
the burner. 

 

Please note! 

Keep the pilot flame free from glow fiber! 
 

 

Start the fireplace as described in the user 
manual. 

 

Assess if the flame distribution is good. 
Move or remove any chips.. 

 

Install the front glass and check the fire 
image. 

 

6.2

 

Pebbles / Grey stones 

See the supplied decoration instruction card or 
chapter 18.3 or 18.4: 
 
Divide the pebbles / grey stones over the entire 
bottom. Avoid a double layer! 
 

 

Please note! 

Keep the pilot flame free from pebbles / grey 
stones! 

 

 

Start the fireplace as described in the user 
manual. 

 

Assess whether the flame distribution is 
good. Move or remove any pebbles / grey 
stones. 

 

Install the front glass and check the fire 
image. 

 

7

 

Checking the installation 

 

Checking for gas leaks 

 

Check with a gas leak finder all connections and 
pipes for gas leakage. 
 

Check primary- and burner pressure

 

Check if the primary pressure correspond to the 
data on the rating plate. 

 

Measuring the primary pressure: 

 

Close the shutoff valve. Turn the 
measuring nipple “

A

” (fig. 1.5) a few turns 

to open and connect a measuring hose to 
the gas regulator. 

 

Take this measurement when the 
fireplace runs at high and low settings.  

 

Do not connect the unit if the pressure is 
too high (+20%). 

 
Measuring the burner pressure: 
Check the burner pressure only with proper 
primary pressure. 

 

Turn measuring nipple “

B

” (fig. 1.5) some 

turns open and connect a measuring hose 
to the gas regulator. 

 

The pressure must correspond to the 
value indicated in the technical 

Summary of Contents for Aspect Premium RD L

Page 1: ...Installation manual Aspect Premium ST L Aspect Premium ST XL ENG 40010936 2016 ...

Page 2: ...Installation manual Aspect Premium ST L XL 1 ...

Page 3: ...Installation manual Aspect Premium ST L XL 2 ...

Page 4: ...Installation manual Aspect Premium ST L XL 3 1 0 1 1 1 2 1 3 1 4 1 5 ...

Page 5: ...Installation manual Aspect Premium ST L XL 4 1 6 1 7 1 8 2 0 2 1 2 2 2 3 X Y ...

Page 6: ...Installation manual Aspect Premium ST L XL 5 2 4 2 5 2 6 2 7 2 8a ...

Page 7: ...Installation manual Aspect Premium ST L XL 6 2 8b ...

Page 8: ...Installation manual Aspect Premium ST L XL 7 ...

Page 9: ...ns Please note It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficien...

Page 10: ... the desired outlet meets the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and balconies Roof edges with the exception of the ridge edge see chapter 15 C11 outlet via facade Through a wall or façade use a Faber wall outlet Depending on the flue calculation this can...

Page 11: ... the flue gas exhaust material 40011968 The distance to combustible materials must be min 50mm calculated from outside of the flue material Never start immediately with length adjustable concentric flue material on the appliance Horizontal sections should be installed to allow a slope towards the fireplace 3 degrees Build the system from the fireplace If this is not possible you can make use of an...

Page 12: ...w fiber Glow fiber gives a decorative glow effect Pull the glow fiber apart and spread it between the logs on the burner Please note Keep the pilot flame free from glow fiber Start the fireplace as described in the user manual Assess if the flame distribution is good Move or remove any chips Install the front glass and check the fire image 6 2 Pebbles Grey stones See the supplied decoration instru...

Page 13: ...n the built in frame and the front glass fig 1 6 X measuring pipe air supply Y measuring pipe flue gas The ratio CO2 and CO must not be greater than 1 100 Example CO2 is 4 and CO is 400ppm measured at the highest point If the ratio is greater than 1 100 or flue gases are measured in the air supply check the points in section 7 1 8 Instructions for client Recommend that the fire should be checked a...

Page 14: ...ation in the drawings fig 12 1 12 2 and 12 3 Total Horizontal Length THL THL is the Total Horizontal Length and consists of elbows and pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are...

Page 15: ...20 x x x x x x x 11 80 20 50 20 30 20 30 20 x x x x x x x 12 80 20 50 20 30 20 30 20 x x x x x x x 13 80 20 50 20 40 20 30 20 x x x x x x x 14 80 20 50 20 40 20 30 20 x x x x x x x 15 80 20 50 20 40 20 30 20 x x x x x x x 16 80 20 50 20 40 20 30 20 x x x x x x x 17 80 20 50 20 40 20 30 20 x x x x x x x 18 80 20 50 20 40 20 30 20 x x x x x x x 19 80 20 50 20 40 20 30 20 x x x x x x x 20 80 20 50 20...

Page 16: ...0 4 80 4 80 4 75 4 70 4 65 4 65 4 60 4 50 4 50 4 40 4 11 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 50 4 40 4 12 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 13 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 14 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 15 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 4 16 80 4 80 4 80 4 75 4 70 4 70 4 65 4 65 4 60 4 60 4 50 ...

Page 17: ...40 20 x x x x x x x 11 50 20 60 20 50 20 50 20 x x x x x x x 12 60 20 70 20 60 20 60 20 x x x x x x x 13 70 20 80 20 70 20 70 20 x x x x x x x 14 80 20 80 20 80 20 80 20 x x x x x x x 15 80 20 80 20 80 20 80 20 x x x x x x x 16 80 20 80 20 80 20 80 20 x x x x x x x 17 80 20 80 20 80 20 80 20 x x x x x x x 18 80 20 80 20 80 20 80 20 x x x x x x x 19 80 20 80 20 80 20 80 20 x x x x x x x 20 80 20 80...

Page 18: ...70 4 70 4 60 4 50 4 50 4 40 4 30 4 x x x 11 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 12 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 13 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 14 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 15 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 16 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 17 80 4 80 4 70 4 70 4 60 4 50 4 40 4 30 4 x x x 18 80 4 80 4 70 ...

Page 19: ...Installation manual Aspect Premium ST L XL 18 12 Examples flue materials ...

Page 20: ... 1 5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizo...

Page 21: ...he installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In ca...

Page 22: ... efficiency index EEI 81 81 81 Type heating output control room temperature no no no no yes no Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day time switch With opti...

Page 23: ...nergy efficiency index EEI 83 83 83 Type heating output control room temperature no no no no yes no Diameter outlet inlet 130 200 Technical data Type indication s Aspect Premium RD XL Aspect Premium ST XL Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW ...

Page 24: ...Position outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Sho...

Page 25: ...Installation manual Aspect Premium ST L XL 24 16 Troubleshooting guide ...

Page 26: ...Installation manual Aspect Premium ST L XL 25 ...

Page 27: ...Installation manual Aspect Premium ST L XL 26 17 Dimensional drawings 17 1 Aspect Premium ST L ...

Page 28: ...Installation manual Aspect Premium ST L XL 27 17 2 Aspect Premium ST XL ...

Page 29: ...Installation manual Aspect Premium ST L XL 28 17 3 Remote access door article number A9299463 ...

Page 30: ...Installation manual Aspect Premium ST L XL 29 17 4 Ventilation grid article number A9296400 ...

Page 31: ...Installation manual Aspect Premium ST L XL 30 17 5 Adjustable feet article number A9319696 ...

Page 32: ...Installation manual Aspect Premium ST L XL 31 18 Decoration instruction card 18 1 Log set Aspect Premium ST L ...

Page 33: ...Installation manual Aspect Premium ST L XL 32 18 2 Log set Aspect Premium ST XL ...

Page 34: ...Installation manual Aspect Premium ST L XL 33 18 3 Pebbles 18 4 Grey stones ...

Page 35: ......

Page 36: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: