Installation manual Aspect Premium ST L,XL
11 <
<
<
<
Installation and finishing
Please note!
Take into account a minimum distance of
2mm due to expansion of the fireplace.
Take into account the thickness of any
finishing layer!
5
Removing glass
Remove the cover strips on both sides.
(see fig. 2.0);
Remove the cover strip on the bottom.
(see fig. 2.1);
Place the suction cups on the glass (see
fig. 1.8);
Remove the sealing cord (see fig. 2.2);
Remove the glass cord lists on both sides.
(see fig. 2.3);
Slide the glass upwards to release the
lower edge from the slot. Now move the
lower edge of the glass forward and lower
the glass into the opening between the
inner frame and the appliance. (see fig.
2.4 and 2.5).
Pull the top of the glass towards to you
and lift up to remove. (see fig. 2.6).
For replacing the glass repeat the steps in reverse
order.
Please note!
Avoid fingerprints on the glass, these are no
longer removable once the fire is used.
6
Placing decoration material
Please note!
It is not permitted to use other or to add
more material in the combustion
chamber.
Do not throw the decoration material on
the burner at once. it is possible that the
burner gets clogged.
6.1
Log set
See the supplied decoration instruction card or
chapter 18.1 or18.2:
Place the log set.
Distribute the black and grey chips around
the burner.
Keep the pilot flame free from chips.
Glow fiber
Glow fiber gives a decorative glow effect. Pull the
glow fiber apart and spread it between the logs on
the burner.
Please note!
Keep the pilot flame free from glow fiber!
Start the fireplace as described in the user
manual.
Assess if the flame distribution is good.
Move or remove any chips..
Install the front glass and check the fire
image.
6.2
Pebbles / Grey stones
See the supplied decoration instruction card or
chapter 18.3 or 18.4:
Divide the pebbles / grey stones over the entire
bottom. Avoid a double layer!
Please note!
Keep the pilot flame free from pebbles / grey
stones!
Start the fireplace as described in the user
manual.
Assess whether the flame distribution is
good. Move or remove any pebbles / grey
stones.
Install the front glass and check the fire
image.
7
Checking the installation
Checking for gas leaks
Check with a gas leak finder all connections and
pipes for gas leakage.
Check primary- and burner pressure
Check if the primary pressure correspond to the
data on the rating plate.
Measuring the primary pressure:
Close the shutoff valve. Turn the
measuring nipple “
A
” (fig. 1.5) a few turns
to open and connect a measuring hose to
the gas regulator.
Take this measurement when the
fireplace runs at high and low settings.
Do not connect the unit if the pressure is
too high (+20%).
Measuring the burner pressure:
Check the burner pressure only with proper
primary pressure.
Turn measuring nipple “
B
” (fig. 1.5) some
turns open and connect a measuring hose
to the gas regulator.
The pressure must correspond to the
value indicated in the technical
Summary of Contents for Aspect Premium RD L
Page 1: ...Installation manual Aspect Premium ST L Aspect Premium ST XL ENG 40010936 2016 ...
Page 2: ...Installation manual Aspect Premium ST L XL 1 ...
Page 3: ...Installation manual Aspect Premium ST L XL 2 ...
Page 4: ...Installation manual Aspect Premium ST L XL 3 1 0 1 1 1 2 1 3 1 4 1 5 ...
Page 5: ...Installation manual Aspect Premium ST L XL 4 1 6 1 7 1 8 2 0 2 1 2 2 2 3 X Y ...
Page 6: ...Installation manual Aspect Premium ST L XL 5 2 4 2 5 2 6 2 7 2 8a ...
Page 7: ...Installation manual Aspect Premium ST L XL 6 2 8b ...
Page 8: ...Installation manual Aspect Premium ST L XL 7 ...
Page 19: ...Installation manual Aspect Premium ST L XL 18 12 Examples flue materials ...
Page 25: ...Installation manual Aspect Premium ST L XL 24 16 Troubleshooting guide ...
Page 26: ...Installation manual Aspect Premium ST L XL 25 ...
Page 28: ...Installation manual Aspect Premium ST L XL 27 17 2 Aspect Premium ST XL ...
Page 29: ...Installation manual Aspect Premium ST L XL 28 17 3 Remote access door article number A9299463 ...
Page 30: ...Installation manual Aspect Premium ST L XL 29 17 4 Ventilation grid article number A9296400 ...
Page 31: ...Installation manual Aspect Premium ST L XL 30 17 5 Adjustable feet article number A9319696 ...
Page 33: ...Installation manual Aspect Premium ST L XL 32 18 2 Log set Aspect Premium ST XL ...
Page 34: ...Installation manual Aspect Premium ST L XL 33 18 3 Pebbles 18 4 Grey stones ...
Page 35: ......