Version 3/08 - Page 5
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
3
3/8”
min
14
3/8”
max
23
5/8”
2
5/8”
36”
FIGURE 4
DUCTED
DIMENSIONS
x
min & max ceiling height examples
x = 30"
min
7'
11 5/8"
max
8'
10 5/8"
x = 28"
min
7'
9 5/8"
max
8'
8 5/8"
x = 26"
min
7'
7 5/8"
max
8'
6 5/8"
x = 24"
min
7'
5 5/8"
max
8'
4 5/8"
The Axia Isola chimney is highly
adjustable and designed to meet varying
ceiling heights as indicated in
FIGURE
4
. The chimney can be adjusted for
ceilings between 7' 5 5/ 8" and 8' 10 5/
8" depending on the distance between
the bottom of the hood and the cooktop
(distance x in FIGURE 4)
.
DUCTED
INSTALLATION DIMENSIONS
(vented to the outside)
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of a grate on the
back of the lower chimney. Ductless installations require a
Ductless Conversion Kit
, available from your dealer.
WARNING!
BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL
BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.
WARNING
DUE TO THE SIZE
AND WEIGHT OF THIS
RANGEHOOD, THE
SUPPORT MUST BE
FIRMLY ATTACHED TO
THE CEILING. For plaster
or sheet rock ceilings, the
support must be attached
to the joists. If this is not
possible, a support structure
must be built behind the
plaster or sheet rock. The
manufacturer assumes no
responsibility for injury or
damage caused by improper
installations.
!