Version 12/04 - Page 7
PREPARE THE WALL
1.
Disconnect and move freestanding range from cabinet open-
ing to provide easier access to rear wall. Put a thick, protective
covering over cooktop, set-in range or countertop to protect from
damage or dirt.
2.
Determine and clearly mark with a pencil the center line on the
wall where the rangehood will be installed.
3.
Based on your ceiling height and/or personal preference,
determine the distance you would like between the bottom of the
hood and the cooktop
(distance X in FIGURE 4 OR 5)
. Draw a
horizontal line the height of
distance X
plus 12 9/16"
(as indicated
in FIGURE 6A)
.
FIGURE 6A - INSTALLATIONS WITH NO BACKSPLASH
3.
Hook the body on to the MOUNTING SCREWS
(D in FIG-
URE 7)
and fully tighten the MOUNTING SCREWS.
4.
Adjust the leveling screws to level the CANOPY SEC-
TION.
5.
For ducted installations, the DAMPER
(H in FIGURE 1)
must be attached to the exhaust opening on the top of the
CANOPY SECTION. Connect the ductwork and seal all
connections with duct tape.
PROCEED TO
"FOR ALL INSTALLATIONS"
ON NEXT
PAGE
FIGURE 7
FIGURE 6B - INSTALLATIONS W/ 24" OR 30" HIGH BACKSPLASH
AND REQUIRED BACKSPLASH ADAPTER
5.
Place the LOWER CHIMNEY MOUNTING BRACKET
(E)
on the wall as shown at 16 3/8" below the upper bracket,
aligning the center notch with the vertical center line. Mark
the wall at the centers of the holes in the bracket.
6.
Install the CHIMNEY MOUNTING BRACKETS
(E)
on the
wall using the MOUNTING SCREWS
(D)
provided.
7.
For the most secure installation, the MOUNTING SCREWS
(D)
which mount the CANOPY SECTION
(A in FIGURE 1)
should be installed into wood. Mark the wall along the hori-
zontal line 4 9/16" in from the center line on either side
(as
indicated in FIGURE 6A or 6B)
and install the MOUNTING
SCREWS into the wall leaving about 1/4" gap between the
wall and the head of the screw.
8.
For ducted installations, determine and make all necessary
cuts in the wall for the ductwork. Install the ductwork before
the rangehood.
9.
Determine the proper location for the Power Supply Cable
by making sure it:
a)
Allows the LOWER CHIMNEY COVER to hide the Field
Wiring Compartment.
b)
Does not have ductwork blocking your access to the Field
Wiring Compartment.
Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply
Cable. Use caulking to seal around the hole. DO NOT turn
on the power until installation is complete.
For installations using the
24" or 30" High Backsplash
and
Back-
splash Adapter
, draw a horizontal line
(as indicated in FIGURE
6B)
12 9/16" above the top of the
Backsplash Adapter.
INSTALL THE RANGEHOOD
1.
USING TWO HANDS, remove the grease filters from the
unit by pulling the knob forward while turning it to the left,
releasing the locking lever.
2.
Before mounting the CANOPY SECTION, tighten the two
leveling screws located near the CANOPY SECTION mounting
points
(as indicated in FIGURE 7)
.
4.
Place the UPPER CHIMNEY MOUNTING BRACKET
(E)
on
the wall as shown 1/16" from the ceiling, aligning the center
notch with the vertical center line. Mark the wall at the centers
of the holes in the bracket.