UK/IRL
>
>
>
>
37
9
Final check and handing over
To ensure safe and efficient operation of the appliance, it is necessary to carry out routine
servicing at regular intervals. It is recommended, that the fire is inspected/serviced by a
competent person at least once a year.
Important:
turn off the gas supply before commencing any servicing.
Always test for gas soundness after refitting the appliance.
The appliance and the flue connection have to be checked for gas and
smoke soundness after installation.
9.1
Routine servicing
1.
Clean (if necessary):
-
the pilot system;
-
the burner;
-
the combustion chamber;
-
the glass.
2.
Check the log lay and replace the embers (if applicable).
3.
Do the functional test as described at page 34.
4.
Check the flue system and terminal on damage and soundness (visual
inspection)
9.1.1
Cleaning the glass
Depending on the intensity of use, you can get a deposit on the glass.
Normally this can be removed with an ordinary dry towel. If necessary
special ceramic glass cleaner (ceramic cook-top cleaner) can be used. To
clean the glass:
1.
Remove the glass as described in paragraph 4.5;
2.
Clean the glass. Handle the glass with clean hands, wear gloves if
possible;
3.
To fit the glass, proceed in reverse order. Make sure that:
•
the log set has been installed correctly before fixing the glass.
•
the glass sealing rope is in good condition and makes an effective
seal
Summary of Contents for BF80S
Page 2: ...UK IRL 2 ...
Page 45: ...UK IRL 45 User guide ...
Page 46: ...UK IRL 46 ...
Page 55: ...UK IRL 55 ...