L
10 <
<
<
<
4.5
Mounting the smoke emission outlet materials
•
In case of a wall or roof terminal, the hole must be at least 5 mm bigger than the
diameter of the flue material.
•
Horizontal parts must be installed at a (3 degree) slope up away the appliance.
•
Build up the system from the appliance. If this is not possible, you should make use
of a adjustable pipe .
•
For fitting the system a ½ metre cut-down pipe should be used. Make sure the
inner pipe is always 2 cm longer than the outer pipe. Wall and roof terminal are
also shortened. These parts must be secured with a self tapping screw.
•
Do not insulate but ventilate bild-in flue material (approx.100cm2)
4.6
Building a false chimney breast.
Before constructing the chimney breast we advise you to perform a function test with the
appliance as described in chapter 7 “checking the installation”
4.7
False Chimney breast
•
Construct the false chimney breast from non-combustible material in combination
with metal profiles or of brickwork / aerated concrete bricks.
•
Take the grills and the service panel into account (see fig. 1.1 and 1.2). Place a
protective shield made of non-inflammable material above the grills (see fig. 1.1
A).
•
Always use a lintel if the chimney breast is constructed of brickwork. These should
not be placed directly onto the appliance .
4.8
Frameless
•
Construct the chimney breast against the build-in frame (see fig. 1.1 B).
Keep a minimum margin of 3 mm between chimney breast and the appliance in
connection with the expansion of the appliance
•
The depth of the recess into the chimney breast has no influence on the removal of
the glass.
4.9
surround
•
Take anomalous installation sizes into account. ( see dimension drawing)
•
Consult the installation manual that is always supplied with the surrounds
Summary of Contents for Clear
Page 1: ...Clear 40010631 0938 Installation guide ENG ENG ...
Page 2: ...L 1 1 1 1 2 1 3 1 4 1 5 A ...
Page 3: ...L 2 A B 2 1 2 2 2 3 2 4 2 5 C ...
Page 4: ...L 3 3 1 3 2 3 3 ...
Page 22: ...L 21 14 Dimension of the appliance ...
Page 23: ...L 22 15 Dimension of the surround Wirdum 770 ...
Page 24: ...L 23 16 Dimension Ventilation Grills ...
Page 25: ...L 24 17 Dimension Service Hatch ...
Page 26: ...L 25 ...
Page 27: ...26 L ...