1 2
12 Outlet position
>
Please note:
These rules apply only for the proper functioning of the unit, for
ventilation and environmental protection you need to comply with
the applicable rules as defined in the building Act.
I n s t a l l a t i o n I n s t r u c t i o n s
Location
Position outlet
Distance mm
D
Under a gutter
500
E
Under a roof edge
500
F
Under a carport or balcony
500
G
Vertical downpipe
300
H
Inside and outside corners
500
J
From wall surface to a wall outlet
1000
K
Two gable outlets against over each other
1000
L
Distance between two roof outlets
450
M
Two roof outlets above each other on a pitched roof
1000
N
Two gable outlets next to each other
1000
Short roof terminal.
Only for existing
Chimney connection
Extension pipe over roof