1 5
YES
NO
YES
NO
YES, the fire works OK
Fire can be switched
off with the remote?
- Check complete wiring
about thermocouple circuit.
- Replace faulty parts.
- RESET the receiver.
- Gas vlave broken, poor or
loose contact.
- Short circuit in wiring.
- Install a ground cable from
the gas valve to the
appliance.
Optional:
Step burner function can
be turned ON and OFF.
(only with remote)
- RESET the receiver
- Check the wiring from
solenoid valve to receiver.
- Faulty solenoid valve.
- Faulty receiver.
- Repaire the wiring.
- Replace solenoid valve.
- Replace receiver.