background image

CRIS24SS300

Installation Instructions

Use and Care Information

Instructions d'installation

Utilisez et d'entretien

Instrucciones de instalación

Información de uso y cuidado

CRISTAL 24"

Version 07/11 - Page 1

READ  THESE  INSTRUCTIONS  BEFORE  YOU  START  INSTALLING  THIS  RANGEHOOD

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:  a) Never leave surface units unattended at high 

settings. Boilovers cause smoking and greasy spillovers that may ignite.  Heat oils slowly on low or medium setting.  b) 

Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper

-

corn Beef Flambé).  c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter.  d) 

Use proper pan size.  Always use cookware appropriate for the size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE 

THE FOLLOWING:  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner.  BE 

CAREFUL TO PREVENT BURNS.  If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT.  

NEVER PICK UP A FLAMING PAN - You may be burned.  DO NOT USE WATER, including wet dishcloths or towels - a 

violent steam explosion will result.  Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and 

you already know how to operate it.  2. The fire is small and contained in the area where it started.  3. The fire department 

is being called.  4.  You can fight the fire with your back to an exit.

ALL  WALL  AND  FLOOR  OPENINGS  WHERE  THE  RANGEHOOD  IS  INSTALLED  MUST  BE  SEALED.

This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface or countertop.  

This minimum clearance may be higher depending on local building code.  For example, for gas ranges, a minimum of 30" may 

be required.  The maximum depth of overhead cabinets is 13".   Overhead cabinets on both sides of this unit must be a minimum 

of 18" above the cooking surface or countertop.  Consult the cooktop or range installation instructions given by the manufacturer 

before making any cutouts.  

LISEZ  BIEN  CETTE  FICHE  AVANT  D'INSTALLER  LA  HOTTE

AVERTISSEMENT - POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLE DE CUISSON : a) Ne jamais laisser 

un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale; un renversement/

débordement de matière graisseuse pourrait provoquer une inflammation et le génération de fumée. Utiliser toujours une 

puissance de chauffage moyenne ou basse pour le chauffage d’huile. b) Veiller à toujours faire fonctionner le ventilateur 

de la hotte lors d’une cuisson avec une puissance de chauffage élevée ou lors de la cuisson d’un mets à flamber (i.e. 

Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Nettoyer fréquemment les ventilateurs d’extraction. Veiller 

à ne pas laisser de la graisse s’accumuler sur les surfaces du ventilateur ou des filtres. d) Utiliser toujours un ustensile 

de taille appropriée. Utiliser toujours un ustensile de taille adapté à la taille de l’élément chauffant.
AVERTISSEMENT: - POUR PRÉVENIR LES BLESSURES EN CAS DE FEU SUIVRE LES RECOMMANDATIONS SUIVANTES:  

ÉTOUFFEZ LE FEU avec un couvercle métallique et fermez le brûleur.  Si le feu ne s'éteint pas tout de suite, QUITTEZ 

LES LIEUX ET APPELEZ LES POMPIERS.  NE TOUCHEZ JAMAIS UNE CASSEROLE EN FLAMMES.  N'UTILISEZ JAMAIS 

DE L'EAU ou un torchon mouillé pour éteindre le feu - ce qui pourrait causer une explosion de vapeur.  N'utilisez un 

extincteur que si: 1.  Vous avez un modèle ABC et vous connaissez bien son mode d'emploi.  2.  Le feu est petit et peu 

répandu.  3.  Les pompiers sont déjà prévenus.  4.  Vous avez une sortie derrière vous.

TOUTE  OUVERTURE  DANS  LE  MUR  OU  LE  PLANCHER  À  PROXIMITÉ  DE  LA  HOTTE  DOIT ÊTRE SCELLÉ

Gardez 24 po. de hauteur entre le bas de la hotte et la surface de cuisson. Cette hauteur minimum peut être plus haute suivant le 

code municipal.  Par exemple, les cuisinières à gaz peuvent requérir 30 po. de hauteur.  Les armoires au-dessus ne dépasseront 

pas 13 po. de profondeur.  Les armoires au-dessus de chaque côté devront être au moins à 18 po. au-dessus de la surface de 

cuisson.  Consultez la fiche technique avant de découper les armoires.  

CRISTAL 24"

Slideout Rangehood

• Installation Instructions

• Use and Care Information

READ  AND  SAVE  THESE  INSTRUCTIONS

The Installer must leave these instructions with the homeowner.  

The homeowner must keep these instructions for future reference 

and for local electrical inspectors' use.

Summary of Contents for Cristal 24 SS

Page 1: ...s at least 24 of clearance between the bottom of the ra This minimum clearance may be higher depending on local building code For be required The maximum depth of overhead cabinets is 13 Overhead cabi...

Page 2: ...RNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FO...

Page 3: ...a fire WARNING Cold Weather installations An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduc...

Page 4: ...with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded Failure to follow electrical requirements may result in a fire WARNING ELECTRICALREQUIREMENTS A 120 vo...

Page 5: ...ht Blower Fil al Air Outlet grille lement on Components 16 x 1 3 4 8 x 6 16 ntation n Manual EN 7 7 DIMENSIONS and MAIN PARTS Components Ref Q ty Product Components 1 1 Hood Body complete with Control...

Page 6: ...space FIGURE 2A 45 Elbow 90 Elbow 90 Flat Elbow Wall Cap FIGURE A 9 Feet Straight Duct 2 90 Elbows Wall Cap Total System FIGURE B 3 0 feet 5 0 feet 12 0 feet 0 0 feet VERTICAL DUCTING FIGURE 1 cabinet...

Page 7: ...top setting to the bottom setting by removing the four phillips screws 5 Tighten the rangehood to the cabinet by rotating the screws with a phillips screw driver 6 A metal trim strip FIGURE 6 is incl...

Page 8: ...his appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can resul...

Page 9: ...uding long periods A N I N G M E T A L S E L F S U P P O R T I N G G R E A S E F I L T E R S r s m u s t b e c l e a n e d e v e r y 2 m o n t h s o f o p e r a t i o n o r e q u e n t l y f o r p a r...

Page 10: ...oximately every 4 months of operation or more frequently with heavy usage Openthevisorbypullingit RemovetheFilter pushingittowardsthebackoftheunitandatthesame timepullingdownward RemovethesaturatedAct...

Page 11: ...CN3 RED org VLT org LB WH A GR CN2 WHT WHT BRW BLU 0 1 2 3 SW2 RED 1 2 3 6 5 4 7 8 9 PNK BLU PNK BK BR CN1 RED BRW SIDE INSERT CABLE SW1 BLK 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 WHT BLU BLK GRY 6 3u...

Page 12: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Page 13: ...apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n utilisez jamaisceventilateurenassociationavecundispositifder glagedevite...

Page 14: ...mats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour r duire le flux d air froid inverse ainsi qu une barri re thermique non m tallique pour r duire la co...

Page 15: ...ILISEZ PAS une conduite de gaz pour la mise la terre N INSTALLEZ PAS un fusible sur le circuit neutre ou le circuit de mise la terre La pr sence d un fusible dans le circuit neutre ou de mise la terre...

Page 16: ...with Controls Light Blower Fil ctional Air Outlet grille mper ing element allation Components ews 3 16 x 1 3 4 ews 1 8 x 6 16 umentation uction Manual EN 7 7 DIMENSIONS and MAIN PARTS Components Ref...

Page 17: ...ood Drill Bit Pliers Phillips Screwdriver Wire Stripper or Utility Knife Metal Snips Measuring Tape or Ruler Level Pencil Caulking Gun Duct Tape PARTS SUPPLIED FOR INSTALLATION 1 Backdraft Damper 1 Ve...

Page 18: ...vis de mise la terre verte Utiliser les quatre trous fournis et fixer le compartimentdefilage au mur ou l armoire d termin par l emplacement du c ble d alimentation vis non fournies Replacer le couve...

Page 19: ...eil est muni d un cordon pr sentant un fil de mise la terre avec une fiche de mise la terre La fiche doit tre ins r e dans une prise correctement install e et mise la terre AVERTISSEMENT Une mise la t...

Page 20: ...n est situ e derri re la bande frontale R gler 1 pour mettre en circuit ON et O pour mettre hors circuit OFF Bouton de vitesse du ventilateur B FIGURE 10 R gler 1 pour vitesse basse LOW 2 pour vitesse...

Page 21: ...mois d utilisation ou plus souvent en cas d utilisation intensive Ouvrez le panneau coulissant en le tirant Retirezlefiltre enlepoussantsimultan mentversl arri re de l appareil et en le tirant vers le...

Page 22: ...CN3 RED org VLT org LB WH A GR CN2 WHT WHT BRW BLU 0 1 2 3 SW2 RED 1 2 3 6 5 4 7 8 9 PNK BLU PNK BK BR CN1 RED BRW SIDE INSERT CABLE SW1 BLK 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 WHT BLU BLK GRY 6 3...

Page 23: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Page 24: ...cia una salida Basado en Consejos para luchas contra los incendios en las cocinas publicado por NFPA ADVERTENCIA PARAREDUCIRELRIESGODEDESCARGASEL CTRICASOINCEN DIOS nouseesteventiladorconning ndisposi...

Page 25: ...cie de cocci n o encimera Esta campana ha sido aprobada por UL a esta distancia del plano de cocci n Esta distancia m nima puede ser mayor dependiendo de los c digos de construcci n locales Para los p...

Page 26: ...ierra NO conecte a tierra una tuber a de gas NO coloque un fusible en el circuito de neutro o tierra Un fusible en el neutro o circuito de puesta a tierra podr a dar lugar a una descarga el ctrica Con...

Page 27: ...Body complete with Controls Light Blower Fil ters 8 1 Directional Air Outlet grille 10 1 Damper 20 1 Closing element Ref Q ty Installation Components 12a 4 Screws 3 16 x 1 3 4 12e 2 Screws 1 8 x 6 16...

Page 28: ...como sea posible El recorrido del conducto no debe exceder los 35 pies si se coloca con un m nimo requerido de 6 de conducto redondo Calcule la longitud del conducto a adiendo los pies equivalentes e...

Page 29: ...ons have been made properly FIGURE 6 ood he bottom lling tem he drilling m surface all unit as nderneath EN 8 8 The hood support surface must be 8 11 16 above the bottom surface of the wall units Dril...

Page 30: ...que tiene un cable de conexi n a tierra con un enchufe de conexi n a tierra El enchufe debe estar enchufado a un tomacorriente que est instalado y conectado a tierra correctamente ADVERTENCIA una cone...

Page 31: ...t e r s o n e a t a t i m e b y p u s h i n g t h e m t o w a r d s t h e b a c k o f t h e g r o u p a n d p u l l i n g u p a t t h e s a m e t i m e W a s h t h e f i l t e r s t a k i n g c a r e...

Page 32: ...aci n o m s frecuentemente con uso intensivo Abralaviseratirandodeella Retireelfiltro empuj ndolohacialaparteposteriordelaunidadyalmismo tiempotirandohaciaabajo Retirelosfiltrossaturadosdecarb nactiva...

Page 33: ...V CN3 RED org VLT org LB WH A GR CN2 WHT WHT BRW BLU 0 1 2 3 SW2 RED 1 2 3 6 5 4 7 8 9 PNK BLU PNK BK BR CN1 RED BRW SIDE INSERT CABLE SW1 BLK 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 WHT BLU BLK GRY 6...

Page 34: ...r est n garantizados contra cualquier defecto de materiales o mano de obra para el comprador original por un per odo de 1 a o a partir de la fecha de compra original requiere prueba de compra Esta gar...

Page 35: ...35...

Page 36: ...991 0531 907_01 180312 D00004241_00...