11 <
<
<
<
UK
IRL
3.7
Using an existing chimney.
You can connect the appliance onto an existing chimney. The existing chimney then
functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs
the flue function.
Requirements:
•
Any existing chimney used as an air supply must only service this appliance.
•
A chimney that has previously been used for solid fuel must be swept before use.
•
The existing chimney needs to be airtight.
•
The existing chimney needs to have an opening of min. 150 x 150 mm.
•
The chimney needs to be intact and well looked after.
•
Use the adjustable roof-mounted-terminal especially made for this, and the
chimney connection set.
For more information see the manual `Chimney Connection Set` delivered with the set.