4.1
Gas Connection
•
Installation pipes should be in accordance with BS 6891. Pipe work from the meter
to the appliance must be of adequate size.
•
The complete installation including the meter must be tested for soundness and
purged as described in the above code.
•
A means of isolation must be provide in the supply to facilitate servicing. The
connection should be made in 8 mm copper or similar semi flexible tube. (max 1
meter). Ensure that the gas pipe does not interfere with the removal or
replacement of the burner tray or of the controls. The gas connection is nut and
olive suitable for 8 mm pipe.
4.2
Electrical connection
If the adapter is used a wall socket 230VAC – 50Hz must be mounted in the close
neighbourhood of the hearth.
4.3
Preparation of the appliance
•
Remove the appliance from the crate and the pallet. Make sure you don’t damage
the flexible gas pipes.
•
Remove the glass and take out the separately wrapped parts of the appliance! (see
par.4.3.1.)
4.4
Removing the glass
•
Clear out a safe place to put down the glass.
•
Remove the bottom sealing ledge. (see fig. 3.2 and 3.3)
•
Place the suction cups on the front glass. (see fig. 3.4)
•
Remove the top and bottom sealing cord on the front. (see fig. 3.5)
•
Gently push the glass upwards so that the bottom is free of the groove and now
gradually tilt the glass forwards and downwards. (see fig. 3.6 and 3.7)
•
Remove the bottom grate. (see fig. 3.8)
•
Remove the sealing strip (depending on the version the strip is situated at the left
or at the right; see fig. 3.9)
•
Place a suction cup on the side glass. (see fig. 4.0 )
•
Remove the sealing cord. strip (depending on the version the strip is situated at the
left or at the right; see fig. 4.1)
Summary of Contents for Duet
Page 1: ...DUET Installation Guide IRL UK 40010731 0842 ...
Page 2: ...1 UK IRL General 1 1 1 2 1 3 1 4 1 5 30cm A ...
Page 3: ... 2 UK IRL Duet 2 1 2 2 2 3 2 4 2 5 ...
Page 4: ...3 UK IRL 3 1 3 2 3 3 3 4 3 5 ...
Page 5: ... 4 UK IRL 3 6 3 7 3 8 3 9 4 0 4 1 ...
Page 6: ...5 UK IRL 4 2 4 3 5 1 A ...
Page 24: ...23 UK IRL Appendix E Dimensions Duet R ...
Page 25: ... 24 UK IRL Appendix F Dimension Duet L ...
Page 26: ...25 UK IRL Appendix G Dimensions Duet R with floorplate ...
Page 27: ... 26 UK IRL Appendix H Dimensions Duet L with floorplate ...
Page 28: ...27 UK IRL Appendix J Dimensions Convection grid ...
Page 29: ... 28 UK IRL Appendix K Dimensions Service hatch ...
Page 30: ...29 UK IRL ...
Page 31: ... 30 UK IRL ...