User manual MatriX I.T.C. Honeywell
6 <
<
<
<
Operation I.T.C. “Intelligent Technical
Controller” (fig. 1.4)
The I.T.C. controls, monitors, records the
consumption and if necessary, gives warning and
error codes. The I.T.C. is not connected to the
internet and not accessible to third parties from
the outside. Only in combination with the optional
available Domotica Interface Unit is it possible, if
desired, to realise connection at a great distance.
Control is possible with remote control,
Smartphone or Tablet. All 3 use a Bluetooth
connection with the fire. The latter has a limited
range so that you need to be in the vicinity of the
fire at all times.
Starting procedure
Starting the fire is done according to a built-in
procedure. This procedure may differ per type of
fire. During this procedure no commands can be
entered. This is shown on the remote control by a
white flashing LED and in the App this will be
visible on the display. If a start-up procedure is
aborted by the user or the fire does not ignite at
the end of the start-up procedure, then there is a
waiting period of 30 sec. after switching off before
it will be possible to restart. The waiting time
increases in case of multiple starting attempts.
After 3 full attempts, the I.T.C. is blocked for at
least half an hour. The I.T.C. restores itself after
this half hour. The waiting period is visible in the
App.
If during normal use the fire is switched off it is
possible to switch it on again after 15 seconds.
Automatic internal control of the electronics
The burner control automatically checks the
correct operation twice per 24 hours. After 12
hours the first check takes place, but this is skipped
if the device is actually burning. If the device is
burning at the second attempt 12 hours later, the
device is switched off and switched on again
immediately after checking the safety system and
will return to the position in which the device was
before the test.
Please note!
If it is not possible anymore to operate the fire
using the remote control or App, the fire can
be switched on/off with the on/off button on
the I.T.C., see fig. 1.4. (The latter is located
behind the small service door).
Fire OFF: Press On/Off button briefly.
Fire ON: Press and hold On/Off button until the
LED turns green.
(If released earlier the start is interrupted).
At pressing longer, the flame will change from low
to high and from narrow to wide. Release the
button at the moment when the desired position
has been reached. If the button is not released, the
fire will automatically switch off.
(If the button is pressed longer than 5 min., the
I.T.C. shows an error message that the button
might be broken and that service is desired).
Remote control (fig. 1.0)
The remote control is already connected to the
I.T.C. so that the fire is ready for use. If this is not
the case, follow the instructions in accordance with
section 4.1. With the remote control all the basic
functions can be activated. For the operation of
the thermostat function and to change settings, it
is necessary to use the Faber App on Smartphone
or Tablet. The remote control also functions as a
room thermostat and must therefore be placed in
a suitable place in the supplied cradle.
(See chapter 8).
Remote control button functions
1:
OFF
(top left)
2:
ON
(top right)
3:
Fire lower
(centre left)
4:
Fire higher
(centre right)
5:
Switching step mode(s)
(bottom left)
6:
Glow effect on/off
(bottom right)
The function of button 6 is only available with an
installed Symbio LED module or HPL module.
The LED intensity can be customised by pressing
and holding button 6 and simultaneously briefly
pressing button 3 or 4 one or more times. This new
setting is saved.
Please note!
The fireplace is switched off if the remote
control:
is out of reach of the fireplace;
is no longer connected to the fireplace;
the batteries are empty.