Installation manual e-MatriX mood 800/500 I,II,III and e-MatriX mood 800/650I,II,III 

11 < 

<

 

<

 

<

 

Check the connection by pulling the pipe. Secure 
the connection with the supplied red / or blue 
safety clips. 
 

 

Please note! 
A watertight connection is only guaranteed 
with safety clips. 

 
Disassemble the flexible water pipe 
Remove the red or blue safety clip. 
Push the water pipe in the coupling, hold the 
flange in its position and pull the water pipe out of 
the coupling. 
 
This appliance is equipped with the following 
(overflow) protections: 

 

Electromechanical valve in the control box 
that is controlled by sensors in the water 
tank. 

 

Absorption valve in the Engine that kicks 
in when the water sump has an unexpect-
edly overflow, see fig. 5.0-K. 

4.5

 

LED lighting (optional) 

 
LED bottom lighting 
The bottom lighting, which is located in the bottom 
plate, can be switched on and off with both the re-
mote control and the App. (See user manual). See 
fig. 3.0-FF and 4.0 for the position of the connec-
tion of the led bottom lighting. 
 
LED top lighting 
The top lighting can be switched on and off with 
both the remote control and the app. (See user 
manual). See fig. 3.0-EE and 4.0 for the position of 
the connection of the top lighting. 
 
Removing the bottom plate with LED lighting 
 

 

Please note! 
To prevent damage / scratches, it is strongly 
recommended to protect the cover strip, see 
fig. 4.0-A. Should scratches nevertheless oc-
cur, this can only be repaired with spray paint 
(Order number: 09000026). 

 

 

Remove the decoration set; 

 

Lift the bottom plate in the middle and let 
it rest carefully at the front of the fire. See 
fig. 4.0. 

 

Loosen the plug connection, for this press 
the retaining clip of the plug. Now remove 
the bottom plate. 

 
 
 
 

Install LED bottom lighting 

 

Lift the bottom plate in the middle and let 
it rest carefully at the front of the fire. See 
fig. 4.0. 

 

Insert the plug into the correct connector 
of the terminal block (see fig. 3.0-FF and 
4.0) and carefully place the bottom plate. 
(Check that the cable will not block the 
outflow opening (fire opening) of the En-
gine). 

4.6

 

Test mode 

Do a performance test (see chapter 7) and check 
all water connections for leaks, before installing 
the decoration set and the front glass. 
 
Functional test via the ITC-V2 app 
(Only possible in dealer setting). 
Make sure the ITC-V2 app is connected to the fire. 
Navigate to Menu -> Diagnostics / Test mode and 
push “Activate”, see fig. 6.0 to 6.3. 
 
The engine can be tested for function. 
 
All components are also checked by a self-test in 
the normal starting procedure. 
Any error messages are displayed in the App. 
 
Click on the "exclamation mark" symbol at the top 
left of the screen for additional information about 
the notification. 

4.7

 

Built-in structure and ventilation 

requirements 

 

The construction may not rest on the fire. 

 

Take into account the thickness of any fin-
ishing layer! 

 

Keep a minimum distance of 10mm be-
tween built-in frame and false chimney 
breast when using combustible material, 
see fig. 1.4. 

 

Take into account a minimum distance of 
2mm due to expansion of the fireplace, 
see fig. 1.4. 
 

Ventilation 

 

The e-MatriX needs a minimum free space 
of 50mm above the fire. 

 

The e-MatriX needs a minimum ventila-
tion of 210cm² underneath the fire. 

 

 

Summary of Contents for e-MatriX mood 800/500 I

Page 1: ...Installation manual e MatriX mood 800 500 I II III e MatriX mood 800 650 I II III ENG 40012136 2202 ...

Page 2: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 2 ...

Page 3: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 3 1 0 1 1 1 2 1 3 1 4 1 5 ...

Page 4: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 4 1 6 2 0a 2 0b 2 0c 2 1a 2 1b 2 1c 2 2 ...

Page 5: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 5 3 0 4 0 EE FF ...

Page 6: ...d 800 650I II III 6 A EA non return valve B or connector C 1m pipe D Valve E To be cut from a pipe length of 1 meter F Mesh filter G In line fine filter H Control box I 1 5m pipe J Engine e MatriX mood 1 Safety clip 11x 2 Brackets 2x fine filter 3 Elbow coupling 4x 5 0 ...

Page 7: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 7 6 0 6 1 6 2 6 3 7 0 7 1 7 2 7 3 8 0 ...

Page 8: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 8 8 0 8 1 8 2 8 3 8 4 8 5 8 6 9 0 ...

Page 9: ...g appliance by its design and construction method complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 these cover the essential requirements of EEC Directives 2014 35 EU and 2014 30 EU Product electric fire Opti myst Model e MatriX mood 800 500 I II III e MatriX mood 800 650 I II III This declaration w...

Page 10: ... power supply Control box to Engine D main switch on off E external water pump connection optional Electrical connection Please note Connect all plugs according to the diagram see fig 3 0 AA control box BB Engine CC printed circuit board DD top lighting optional EE bottom lighting optional FF power supply LED GG fan extraction HH fan heating II external water pump optional Lead control cable A fro...

Page 11: ... Lift the bottom plate in the middle and let it rest carefully at the front of the fire See fig 4 0 Loosen the plug connection for this press the retaining clip of the plug Now remove the bottom plate Install LED bottom lighting Lift the bottom plate in the middle and let it rest carefully at the front of the fire See fig 4 0 Insert the plug into the correct connector of the terminal block see fig...

Page 12: ...he included decoration instruction card or Chapter 11 Please note Placing the logs is a meticulous job this deter mines the flame distribution Do not let any decoration material fall into the outflow fire opening The outflow openings may not be completely covered Divide the mini chips over the bottom Place the wooden logs Apply the ash material Fine tuning of the glow bed By placing the decoration...

Page 13: ...h clean water to remove all traces of washing up liquid 12 Clean the nozzle fig 8 4 with a soft brush and flush out thoroughly with water Reverse the steps above to reassemble Cleaning air filter 1 Gently slide the air filter upwards out of its plastic holder see fig 9 0 2 Gently rinse with water in the sink and dry with fabric towel before returning 3 Replace the air filter 4 Place the decoration...

Page 14: ... mood 800 650I II III 14 Technical data 230 V 240 V Input Figures Full Heat 2050 W 2250 W Half Heat 1150 W 1350 W Flame Only 245 W 260 W Standby 5 W 5 W Batteries Remote 2x 1 5 AA V Water Consumption 0 15 L h Inlet Water Pressure 0 5 8 Bar Water Connection or Inch ...

Page 15: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 15 Dimensional drawings 10 1 e MatriX mood 800 500 I e MatriX mood 800 650 I ...

Page 16: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 16 10 2 e MatriX mood 800 500 IIL e MatriX mood 800 650 IIL ...

Page 17: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 17 10 3 e MatriX mood 800 500 IIR e MatriX mood 800 650 IIR ...

Page 18: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 18 10 4 e MatriX mood 800 500 III e MatriX mood 800 650 III ...

Page 19: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 19 10 5 Control box ...

Page 20: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 20 10 6 Wall bracket e MatriX mood 800 500 e MatriX mood 800 650 artikelnummer A9325396 ...

Page 21: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 21 10 7 Remote access door article number A9299463 ...

Page 22: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 22 Decoration instruction card 11 1 e MatriX mood 800 500 e MatriX mood 800 650 ...

Page 23: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 23 ...

Page 24: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: