Installation manual e-MatriX mood 800/500 I,II,III and e-MatriX mood 800/650I,II,III
13 <
<
<
<
therefore can differ from the above men-
tioned.
Cleaning water sump
Please note!
Always press the mains switch of the Con-
trol box to the OFF (0) position, see fig.
1.0-D and disconnect the power supply,
Never use abrasive cleaners.
1.
Remove the front glass, see chapter 5.1.
2.
Remove the decoration set, see chapter 6.
3.
Lift the bottom plate in the middle and let
it rest carefully at front of the fire. See fig.
4.0.
4.
Disconnect the plug connection, pressing
in the plug's locking clip to do so. Remove
the base plate to gain full access to the
engine, see fig. 8.0;
5.
Disconnect the “fill cap” by turning it
clockwise, see fig. 8.1.
6.
Disconnect the transducer cable, see fig.
8.2.
7.
Release the clip on both sides and remove
the nozzle, see fig. 8.3 and 8.4.
8.
Without spilling any water, lift up the wa-
ter sump gently and empty the water
sump, see fig. 8.5.
9.
The transducer is fixed in the water sump
with a plastic clip. Push the clip backwards
gently and remove the transducer, see fig.
8.6.
10.
Put a small amount of washing up liquid
into the water sump and using a soft
brush to clean the sump. Also clean the
transducer, including the disc underneath
the cone. Remove the cone by turning it
clockwise, see fig. 8.7.
11.
When cleaned, thoroughly rinse the water
sump with clean water to remove all
traces of washing up liquid.
12.
Clean the nozzle (fig. 8.4) with a soft brush
and flush out thoroughly with water.
Reverse the steps above to reassemble.
Cleaning air filter
1.
Gently slide the air filter upwards out of
its plastic holder, see fig. 9.0.
2.
Gently rinse with water in the sink and dry
with fabric towel before returning.
3.
Replace the air filter.
4.
Place the decoration set, see chapter 6.
5.
Place the front glass, see section 5.1.
Replacing the transducer
Please note!
Press the mains switch of the Control box to
the “OFF” (0) position, see fig. 1.0-D and dis-
connect the power supply.
1.
Follow the first 9 steps in section “Clean-
ing water sump” in chapter 8.1 to gain ac-
cess and remove the transducer.
2.
Place the new transducer and repeat the
steps above in reverse order.
(Please take note that the transducer ca-
ble will not block the opening of the
cone).
Cleaning mesh filter
1.
Turn off the water supply.
2.
Close the ball valves.
3.
Unscrew the base and clean the filter in-
side.
Replacing in-line filter
1.
Turn off the water supply.
2.
Close the ball valves.
3.
Replace the filter. Note the flow direction
mark on the filter!
8.2
Resetting absorption valve
When the absorption valve (fig. 5.0-K) is activated,
the sponge need to be replaced. The absorption
valve is located on the right front at the bottom of
the Engine.
1.
Take out the sponge.
2.
Fix the cause of the water leakage and re-
move any water at the bottom of the en-
gine.
3.
Place the new sponge and open the ab-
sorption valve by pressing down the white
clamp.