5
Controls
Button Function
Led
L
Turns the lights on/off at maximum strength.
-
T1
Turns the motor on/off at speed one.
Fixed.
Keeping the button pressed for approximately 2 seconds starts/stops the temperature
sensor.
1 flash of LEDs
T2
and
T3
algorithm
activated.
2 flashes of LEDs
T2
and
T3
algorithm
deactivated.
T2
Turns the Motor on at speed two.
Press and hold the button for approximately 5 seconds, with all the loads
turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on. The
relevant LED flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 5 seconds.
The relevant LED flashes once.
Fixed.
T3
Turns the Motor on at speed three.
Press and hold the button for approximately 3 seconds, with all the loads turned
off (Motor and Lights), to perform a reset. The LED
S1
flashes three times.
Fixed.
T4
Turns the Motor on at
INTENSIVE
Speed.
This speed is timed to run for 6 minutes. At the end of this time, the system
returns automatically to the speed that was set before. If it is activated with the
motor turned off, the hood will switch to OFF at the end of the time.
Press and hold for 5 seconds to enable the remote control, indicated by the
LED flashing twice.
Press and hold for 5 seconds to disable the remote control, indicated by the
LED flashing just once.
Fixed.
S1
Signals the Metal Grease Filter saturation alarm, indicating that it is necessary
to wash the filters. The alarm is triggered after the Hood has been in operation
for 100 working hours.
Fixed.
When this is activated, it signals the Activated Charcoal Filter saturation alarm,
indicating that the filter must be changed; the Metal Grease Filters must also
be washed. The Activated Charcoal Filter saturation alarm comes into operation
after the Hood has been working for 200 hours.
Flashing.
WARNING:
the temperature sensor is active when the hood is started. If, when the hood is off, the tempe-
rature detected by the sensor exceeds the set limit, the hood will turn on at speed two. When the tempe-
rature detected by the sensor returns below the threshold value the hood will turn off. In the event of the
temperature not returning below the threshold value for approximately 90 minutes, the hood will turn off (the
sensor is disabled for approximately 15 minutes, after which it will return to the previous setting). If the hood
is adjusted manually (switching on/changing speed) the sensor is disabled and the hood must be turned off.
After turning the hood off, the sensor is disabled for approximately 15 minutes, after which it will return to
the previous setting. The temperature sensor does not guarantee automatic start-up of the hood, as its
operation is influenced by environmental conditions, types of cooking operation, height and installation of
the hood (tested at 530 mm).
WARNING:
the sensor does not work with induction cookers.
Summary of Contents for IN-NOVA-PREM-A90
Page 51: ...51 650 I 120 0 04 RU...
Page 52: ...52 3 8 4...
Page 53: ...53 W W W 2 Z Z...
Page 54: ...54 L T1 2 1 T2 T3 2 T2 T3 T2 5 5 T3 3 S1 T4 6 5 5 S1 100 200 90 15 15 530...
Page 55: ...55 1 5 LR03 AAA...
Page 68: ...68 650 I 120 0 04 3 UK...
Page 69: ...69 8 4 W...
Page 70: ...70 W W 2 Z Z...
Page 71: ...71 L T1 1 2 1 T2 T3 2 T2 T3 T2 2 5 5 T3 3 3 S1 T4 6 5 5 S1 100 200 90 15 15 530...
Page 72: ...72 LR03 AAA 1 5 Luce On Off Luci...
Page 101: ...101 650 mm 120 mm 0 04 mbar GR...
Page 102: ...102 3 mm 8 4...
Page 103: ...103 W W W 2 Z Z...
Page 105: ...105 1 5 V LR03 AAA...
Page 110: ...110 650 I 120 0 04 mbar BG...
Page 111: ...111 3 8 4 W...
Page 112: ...112 W W 2 Z Z...
Page 113: ...113 L T1 2 1 T2 T3 2 T2 T3 T2 5 5 T3 3 S1 3 T4 6 5 5 S1 100 200 2 90 15 15 530...
Page 114: ...114 1 5 V LR03 AAA...
Page 115: ...115 650 1 120 0 04 3 KK...
Page 116: ...116 8 4 W W W 2 Z...
Page 117: ...117 Z...
Page 118: ...118 L T1 2 T2 T3 1 T2 T3 2 T2 5 5 T3 3 S1 T4 6 5 5 S1 100 200 90 15 15 530...
Page 119: ...119 LR03 AAA 1 5...
Page 120: ...120 650 mm I 120 mm 0 04 mbar MK...
Page 121: ...121 3 mm 8...
Page 122: ...122 W W W 2 Z Z...
Page 124: ...124 1 5 V LR03...
Page 127: ...127 Z Pastrojeni aspiratorin duke p rdorur nj coh t lag sht e detergjent t l ngsh m neutral...
Page 130: ...130 650 mm 1 120 mm 0 04 mbar 3 mm SR...
Page 131: ...131 8 4 W W W 2 Z Z...
Page 132: ...132 Led L T1 2 1 T2 T3 2 T2 T 3 T2 5 5 T3 3 S1 T4 6 5 5 S1 100 200 90 15 15 530 mm...
Page 133: ...133 1 5 V LR03 AtAA...
Page 134: ...134 AR 0 04 650 I 120 0 04 3 8 65 I 120 04 0 4 2 W Z 650 I 120...
Page 135: ...135 Z 2 4 2 4 Z 4 W 8 2 4 2 4 2 4 2 4 W W...
Page 136: ...136...
Page 137: ...137 1 5 LR AAA On Off On Off...
Page 138: ......
Page 139: ......
Page 140: ...991 0442 641_01 160412 D002713_00...