RECIRCULATING INSTALLATIONS

For recirculating installations 

(FIGURE 1)

Charcoal Filters

 are necessary.  The 

charcoal filters must be inserted behind the grease filters as indicated in 

(A in FIGURE 

1)

.  Recirculating installations also require some duct work to divert the air out of the 

cabinet.  The duct work must not terminate inside the cabinet.

MAKE YOUR CUT-OUTS

1. 

Disconnect and move freestanding range from cabinet opening to provide easier 

access to upper cabinet and rear wall.  Put a thick, protective covering over cooktop, 

set-in range or countertop to protect from damage or dirt.

2. 

Determine and clearly mark with a pencil the center line on the cabinet  where 

the rangehood will be installed.

3. 

Determine and make all necessary cuts in the wall for the ductwork.  Install the 

ductwork before the rangehood.

4. 

Determine the proper location for the Power Supply Cable.  Use a 1 

1/4"

 Drill Bit 

to make this hole.  Install the cable.  Use caulking to seal around the hole.  DO NOT 

turn on the power until installation is complete.

5.

 Make the cut-out opening where the rangehood will be installed

 (FIGURE 2)

.

26 21/32" WIDTH FOR 28" HOOD, 19 19/32" WIDTH FOR 24" HOOD.

INSTALL  THE  RANGEHOOD

1. 

Remove the rangehood from the carton and place on a flat surface.  Cover the sur

-

face to prevent accidental damage.  Remove all parts including the backdraft damper, 

screws, field wiring box and literature package before discarding the carton.

2. 

Place the round damper into the exhaust opening of the rangehood and press 

down.

3. 

Remove the bottom of the rangehood by pulling on the grey tabs 

(A in FIGURE 

3)

 located on either side.

4. 

Fix the rangehood to the cabinet using the two spring loaded brackets, one on 

each side of the rangehood 

(B in FIGURE  4)

.  Using a philips screwdriver, tighten 

the adjustment screw 

(C in FIGURE 4) 

until the brackets adhere tightly to the surface. 

For thicknesses of LESS than 

3/4", 

insert a block of wood to fill in the gap between 

the cabinet bottom and the spring loaded bracket.

5. 

IMPORTANT:   Also fix the rangehood to the cabinet using the 10 screws provided 

(FIGURE 4)

.  

6.

 Replace the bottom of the rangehood and secure by pushing in the grey tabs 

(A 

in FIGURE 3)

.

7. 

Remove the cover from the field wiring compartment with a phillips screwdriver.  

Feed the Power Supply Cable through the electrical knockout.  Connect the Power 

Supply Cable to the rangehood cable.  Attach the White lead of the power supply 

to the White lead of the rangehood with a twist-on type wire connector.  Attach the 

Black lead of the power supply to the Black lead of the rangehood with a twist-on 

type wire connector. Attach the Power Supply Cable grounding lead to the green screw 

provided. Using the 4 holes provided screw the field wiring compartment to the wall 

or cabinet as dictated by your Power Supply Cable location (screws not provided).  

Replace the cover.

8.

 Connect the ductwork to the damper and seal all connections with duct tape.

9.

 Turn the power supply on.  Turn on the blower and light.  If the rangehood does 

not operate, check that the circuit breaker is not tripped or the house fuse blown.  If 

the unit still does not operate, disconnect the power supply and check that the wiring 

connections have been made properly.

FIGURE 1

FIGURE 2

FIGURE 4

FIGURE 3

FIGURE 7

A

5” round

duct

cabinet

ceiling

inca smart

cabinet

ceiling

soffit

5” round

duct

inca smart

A

Summary of Contents for INCA SMART 24 & 28"GRAY

Page 1: ...URLATABLEDECUISSON a Nejamaislaisser un l ment de la table de cuisson fonctionner sans surveillance la puissance de chauffage maximale un renversement d bordement de mati re graisseuse pourrait provoq...

Page 2: ...cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TOREDUCETHERISKOFFIREORELECTRIC SHOCK do not use this fan with any so...

Page 3: ...cessaire pour tous les appareils combustion Suivez les conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am r...

Page 4: ...des installations avec L Inca HC SS enlevez la section perfor e additionnelle RANGEHOOD DIMENSIONS DIMENSIONS DE LA HOTTE LINER DIMENSIONS DIMENSIONS DU CADRE Pre Planning Your Installation Important...

Page 5: ...OUT WHEN INSTALLING THE STANDARD LINER WITH THE INCA SMART MODEL THIS PERFORATION IS ONLY REMOVED FOR USE WITH THE INCA HC SS MODEL Consider the shape size and weight of the Inca Smart and Liner to d...

Page 6: ...rey tabs A in FIGURE 3 located on either side 4 Fix the rangehood to the cabinet using the two spring loaded brackets one on each side of the rangehood B in FIGURE 4 Using a philips screwdriver tighte...

Page 7: ...er The grease filters are removed by pressing the handle of the filter as indicated in FIGURE6 Whenreplacing makesurethatthefiltersareproperly positioned with the handles in front and visible USE AND...

Page 8: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 9: ...RFORATIONESTSEULEMENT ENLEV E POUR L USAGE AVEC LE MOD LE DE L INCA HC SS INSTALLATIONS AVEC CADRES PI CES FOURNIES POUR L INSTALLATION 1 registre clapet 10 vis Compartiment de filage 1 n cessaire de...

Page 10: ...jeter la bo te 2 Placer le registre rond dans l ouverture d chappement de la hotte et appuyer forte ment sur le registre 3 Retirer le bas de la hotte en tirant sur les pattes grises A de la FIGURE 3 q...

Page 11: ...Retirer les filtres pour la graisse en pressant sur la poign e l avant du filtre tel qu il est illustr la figure 6 Au moment de les replacer s assurer que les filtres soient positionn s ad quatement l...

Page 12: ...r les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de...

Reviews: