background image

13

GB

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

• The manufacturer will not be held liable for any damages resulting

from incorrect or improper installation.

• The minimum safety distance between the cooker top and the

extractor hood is 650 mm.

• Check that the mains voltage corresponds to that indicated on the

rating plate fixed to the inside of the hood.

• For Class I appliances, check that the domestic power supply

guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of
minimum diameter 120 mm. The route of the flue must be as short
as possible.

• Do not connect the extractor hood to exhaust ducts carrying

combustion fumes (boilers, fireplaces, etc.).

• If the extractor is used in conjunction with non-electrical appliances

(e.g. gas burning appliances), a sufficient degree of aeration must
be guaranteed in the room in order to prevent the backflow of
exhaust gas. The kitchen must have an opening communicating
directly with the open air in order to guarantee the entry of clean
air.

USE

• The extractor hood has been designed exclusively for domestic

use to eliminate kitchen smells.

• Never use the hood for purposes other than for which it has ben

designed.

• Never leave high naked flames under the hood when it is in

operation.

• Adjust the flame intensity to direct it onto the bottom of the pan

only, making sure that it does not engulf the sides.

• Deep fat fryers must be continuously monitored during use:

overheated oil can burst into flames.

• The hood should not be used by children or persons not instructed

in its correct use.

MAINTENANCE

• Switch off or unplug the appliance from the mains supply before

carrying out any maintenance work.

• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.

650 mm min.

Summary of Contents for KSEIV96X

Page 1: ...Libretto Istruzioni Instruction Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing NL 42 DE 32 FR 22 GB 12 IT 2 Arco Isola Plus...

Page 2: ...ecommendations contained in this Instruction Manual your appliance will give you constant high performan ce and will remain efficient for many years to come RECOMMENDATIONSAND SUGGESTIONS 13 CHARACTER...

Page 3: ...aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of cl...

Page 4: ...14 GB CHARACTERISTICS Dimensions 650 min 90 135 500 676 70 898 340 150 min 890 max 1170 890...

Page 5: ...Upper frame 7 1b 1 Lower frame 8 1 Air Outlet Grill 9 1 Reducer Flange 150 120 mm 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 14 1 1 Air Outlet Connection Extension 15 1 A...

Page 6: ...ed For concrete ceilings drill for plugs appropriate to the screw size For hollow brick ceilings with wall thickness of 20 mm drill 10 mm For wooden beam ceilings drill according to the wood screws us...

Page 7: ...side thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the suspension point the...

Page 8: ...assemble as described previously Before fixing the hood body to the frame Remove the grease filters from the hood body Remove any activated charcoal filters From below use the 4 screws 12f provided to...

Page 9: ...od is in ELC Electronic Comfort mode the button will not only turn the Ducting motor on but will also disable this function V1 Speed Reduces the operating speed When the button is pressed with the Mot...

Page 10: ...s The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by pushing t...

Page 11: ...ace the metal grease filters Alarm signal activation On the recirulcation version extractor hood the filter saturation alarm is activated during installation or at a later date Switch off the lights a...

Page 12: ...europ enne en mati re de basse tension C E E 73 23 de s curit lectrique ainsi qu aux normes europ ennes C E E 89 336 en mati re de compatibilit lectromagn tique et C E E 93 68 en mati re de label CE...

Reviews: