4
ALL WALL AND FLOOR OPENINGS WHERE THE RANGE HOOD IS INSTALLED
MUST BE SEALED.
This Range Hood requires at least 24" of clearance
between the bottom of the Range
Hood and the cooking surface or countertop. This hood has been approved by UL at this
distance from the cooktop.
This minimum clearance may be higher depending on local building codes. For gas cooktops
and combination ranges, a minimum of 30" is recommended and may be required.
Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking
surface or countertop. Consult the cooktop or range installation instructions given by the
manufacturer before making any cutouts.
MOBILE HOME INSTALLATION The installation of this Range Hood must conform to the
Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See
Electrical Requirements"
• Venting system MUST terminate outside the home.
•
DO NOT
terminate the ductwork in an attic or other enclosed space.
•
DO NOT
use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
•
DO NOT
REVWUXFWWKHµRZRIFRPEXVWLRQDQGYHQWLODWLRQDLU
)DLOXUHWRIROORZYHQWLQJUHTXLUHPHQWVPD\UHVXOWLQD´UH
WARNING
!
VENTING REQUIREMENTS
Determine which venting method is best for your application. Ductwork can extend either
through the wall or the roof.
The length of the ductwork and the number of elbows should be kept to a minimum to
SURYLGHHI´FLHQWSHUIRUPDQFH7KHVL]HRIWKHGXFWZRUNVKRXOGEHXQLIRUP'RQRWLQVWDOO
two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking
WRVHDOH[WHULRUZDOORUµRRURSHQLQJDURXQGWKHFDS
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air
turbulence that greatly reduces performance.
0DNHVXUHWKHUHLVSURSHUFOHDUDQFHZLWKLQWKHZDOORUµRRUIRUH[KDXVWGXFWEHIRUHPDNLQJ
cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut,
then a supporting frame must be constructed.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
&$87,217RUHGXFHULVNRI´UHDQGWRSURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH
– Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces,
or garages.
Cold Weather installations
$QDGGLWLRQDOEDFNGUDIWGDPSHUVKRXOGEHLQVWDOOHGWRPLQLPL]HEDFNZDUGFROGDLUµRZDQGDQRQPH
-
tallic thermal break should be installed to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the thermal break. The break should be as
close as possible to where the vent system enters the heated portion of the house.
3.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
4.
Ducted fans must always be vented to the outdoors.
Summary of Contents for Levante E
Page 6: ...6 RANGE HOOD DIMENSIONS 7 1 4 3 23 15 16 29 15 16 35 15 16...
Page 7: ...7 MIN 24 OVER ELECTRIC MIN 30 OVER GAS Min 24 Min 30 INSTALLATION HEIGHT REQUIREMENTS...
Page 31: ...31 WIRING DIAGRAM E D 9 7 02725 5 1 2 7 5 E 5 2 D 1 7 22 17 51 21752 03 7 1 1 9DF...
Page 38: ...38 DIMENSIONS DE LA HOTTE 7 1 4 3 23 15 16 29 15 16 35 15 16...
Page 63: ...63 SCH MA DE C BLAGE E D 9 7 02725 5 1 2 7 5 E 5 2 D 1 7 22 17 51 21752 03 7 1 1 9DF...
Page 70: ...70 DIMENSIONES DE LA CAMPANA EXTRACTORA 7 1 4 3 23 15 16 29 15 16 35 15 16...
Page 95: ...95 DIAGRAMA DE CABLEADO E D 9 7 02725 5 1 2 7 5 E 5 2 D 1 7 22 17 51 21752 03 7 1 1 9DF...
Page 97: ......
Page 98: ......
Page 99: ......