OpIon   #2   –   Direct   Connect   Kitchen   InstallaIon   (independent   of   HVAC   system)         

*For   general   comfort   and   aestheIcs,   it   is   recommended   that   the   Make-­‐up   Air   Damper   intake   is   located   in   an   area   that   does   not   venIlate   
directly   on   or   into   kitchen   preparatory   or   dining   areas.*   NOTE:   Fresh   Air   Damper   is   always   installed   in   a   separate   duct   than   the   range   hood   
ducIng   

Sizing   the   fresh   air   intake   and   exhaust   duct   symmetrically   will   help   avoid   air   turbulence   and   drag   while   the   internal   air   supply   is   replenished   
during   opera9on   of   the   kitchen   vent   hood.   

During   opera9on   of   the   kitchen   
exhaust,   the   motorized   damper   will   

open   to   allow   fresh   outside   air   to   enter   
the   home.      When   the   exhaust   system   

is   not   in   use   the   motorized   damper   will   
close   and   no   longer   allow   outside   air   
to   enter.   

Outside   fresh   air   inlet   must   be   installed   on   the   
exterior   of   the   house   a   minimum   distance   of   

10g   from   combus9on   vents   and   other   exhaust   
openings.      Locate   the   fresh   air   inlet   away   from   

any   outside   motor,   generator,   pump,   BBQ   grill,   
hearth/fire   pit,   chemical   storage   area,   or   any   
poten9ally   hazardous   exposure   area.   

range   hood   exhausIng   to   the   exterior   of   the   house   

FRESH   OUTSIDE   

AIR   

The   Fresh   Intake   Air   
Damper   should   be   

located   a   minimum   
of   3g      away   from   the   

kitchen   exhaust   
hood.   

The   fresh   air   intake   should   be   located   at   a   

high   point   in   the   kitchen   away   from   any   

cooking/preparaIon/dining   areas.   

Benefits:   

      The   air   is   generally   warmer   in   this   

loca9on,   and   both   cooler   and   warmer   

outside   air   will   diffuse   into   the   room   with   

less   of   an   impact   to   the   occupants   

   HVAC   register   covers   are   installed   at   

ceiling   levels   so   the   grille   cover   for   the   fresh   

air   inlet   will   be   less   obtrusive   to   kitchen   

design   considera9ons   

Contractors   will   be   able   to   access   ajc   

space,   soffits,   and   sub-­‐flooring   between   

levels   for   easier   installa9on   of   duct   work   

   Installing   the   fresh   air   intake   away   from   

ground   level   will   reduce   the   amount   of   

dust,   pollen,   and   allergens   drawn   in   with   

the   outside   air   

The   replenishment   
or   make-­‐up   air   
must   be   drawn   

from   outside   of   the   
home

.      

24V   low   voltage      wiring      required   at   ini9al   rough-­‐in   stage   of   installa9on   (wiring   not   included)

   

                  Range   Hood   

Switch   

Assembly   

Motorized   Fresh   Air   Damper   

Switch   Assembly   must      
be   installed   in   rigid   
ductwork.

   

The   recommended   
loca9on   for   the   Switch   
Assembly   collar   is   in   a   
straight   duct   run   directly   
above   the   kitchen      

exhaust   fan   motor.      

The   actual   loca9on   of   the   make-­‐up   air/fresh   air   damper   will   be   

determined   by   the   spacing   and   architectural   considera9ons   of   each   

individual   residen9al   kitchen   design.      

The   fresh   air   damper   needs   to   

be   installed   in   the   closest   and   most   convenient   locaIon   in   relaIon   

to   the   exhaust   system   that   it   is   being   used   with.   

   The   fresh   air   

damper   inlet   should   not   be   installed   where   it   could   confine   or   restrict   

air   flow   back   into   the   area   where   the   exhaust   fan   is   located.         

TESTING   THE   SYSTEM

   

Once   all   duc9ng   and   wiring   connec9ons   have   been   made   with   this   kit   and   the   range   hood   installa9on   has   also   been   completed,   the   system   

should   be   tested.      Turn   the   range   hood   onto   the   highest   speed   and   confirm   that   the   fresh   air   automa9c   damper   on   the   outside   of   the   home   
opens   to   bring   fresh   air   back   into   the   home.   If   the   “direct   connect”   op9on   has   been   used   where   the   return   air   damper   is   wired   into   the   central   air   
system,   ensure   that   the   system   is   working   in   conjunc9on   with   the   make   up   damper   kit.   A   qualified   HVAC   contractor   should   also   ensure   that   all   
combus9on   equipment   is   opera9ng   and   ven9ng   correctly.   

MAINTENANCE

   

Regular   maintenance   is   required   so   the   system   properly   operates.   Check   ups   and   cleaning   of   duc9ng   parts   are   required   to   ensure   that   fresh   air   
con9nues   to   come   into   the   home.   1)   Clean   the   outside   bird   screen   to   ensure   that   the   fresh   inlet   isn’t   blocked   with   debris.   2)   Have   a   qualified   
HVAC   servicer   provide   check   ups   on   your   central   air   system   including   replacing   dirty   air   filters   to   ensure   filtered   fresh   air   is   coming   inside.   Also   
during   regular   maintenance,   have   this   HVAC   professional   inspect   the   make   up   air   system   for   correct   opera9on.   

Summary of Contents for MUDAMPER10

Page 1: ...way to fresh air is provided 7 This unit is intended to be installed within the home in a loca9on protected from any kind of moisture 8 Do not connect this kit directly to any combus9on appliances 9 Do not operate this system un9l all installa9on guidelines have been adhered to 10 In cold weather climates addi9onal insula9on and vapor barriers are recommended to prevent condensa9on build up 11 Any...

Page 2: ...make up air system or through natural air infiltraIon Return Air Duct Air Circula9on Fan Filter Air Supply Duct Kitchen Range Hood Switch Assembly Motorized Fresh Air Damper Fresh Air Intake on Exterior of House The above wiring diagram is a generalized depic9on Please consult a licensed HVAC or electrical contractor professional prior to ademp9ng any connec9ons to the HVAC system or electrical com...

Page 3: ...en and allergens drawn in with the outside air The replenishment or make up air must be drawn from outside of the home 24V low voltage wiring required at ini9al rough in stage of installa9on wiring not included Range Hood Switch Assembly Motorized Fresh Air Damper Switch Assembly must be installed in rigid ductwork The recommended loca9on for the Switch Assembly collar is in a straight duct run di...

Page 4: ...aIon VerIcal DucIng InstallaIon Inline Blower InstallaIon Inline Fan Motor Remote Blower InstallaIon Exterior Mounted Fan Motor Downdrag Fan Motor Direct Rear DucIng InstallaIon Air Switch InstallaIon Inside Hood DucIng applies to all installaIons ...

Page 5: ...connect all power supply to unit s prior to installa9on or service repair of device 2 Use this unit only in manner intended by manufacturer 3 All applica9ons of device must follow all applicable laws codes regula9ons and standards 4 Installa9on of device must be completed by a cer9fied installa9on expert or HVAC professional 5 For residen9al use only any use beyond factory recommenda9ons voids all ...

Page 6: ...mper closes when the range hood motor is turned off Your Faber range hood will operate effec9vely since there is an adequate supply of fresh air to draw from DOES MY FURNACE OR WATER HEATER GET COMBUSTION AIR FROM THIS SYSTEM No this system only helps to make up air that is exhausted by the range hood HOW DO I KNOW IF I NEED MAKE UP AIR Today s newly constructed homes have very 9ght insula9on which ...

Page 7: ... voie claire à l air frais est fourni This unit is intended to be installed within the home in a location protected from any kind of moisture 7 Ne pas brancher ce kit directement à tous les appareils à combustion 8 Ne pas utiliser ce système jusqu à ce que toutes les directives d installation ont été respectées 9 Dans les climats froids isolation supplémentaire et pare vapeur sont recommandés pour...

Page 8: ...e l air naturel Alimentation en air Fan de Circulation d air Filtrez Fourniture d air Hotte Mettez Assemblée Motorisé frais air Damper Frais d admission d air sur l extérieur de la maison Le schéma de câblage ci dessus est une représentation généralisée S il vous plaît consulter un CVC ou un entrepreneur agréé électrique professionnel avant d essayer toutes les connexions au système CVC ou les com...

Page 9: ...es tiré en l air à l extérieur La reconstitution ou l air d appoint doivent être établis à l extérieur de la maison 24V câblage basse tension nécessaire au stade initial rugueux dans l installation câblage non inclus Hotte Mettez Assemblée Motorisé registre d air frais Assemblée de commutation doit être installé dans conduits rigides L emplacement recommandé pour le col de l Assemblée de commutate...

Page 10: ...n du Ventilateur Moteur monté dans une ligne de ventilateur Installation Ventilateur à Distance Gendarmerie extérieur du moteur du ventilateur Bas projet de moteur de ventilateur Direct Installation Conduits Arrière Installation de commutation air à l intérieur Hotte Conduits appuies à toutes les installations ...

Page 11: ...à l unité s avant l installation ou l entretien réparation de l appareil 2 Utiliser cet appareil uniquement de la manière prévue par le fabricant 3 Toutes les applications de dispositif doivent suivre toutes les lois les codes les règlements et les normes 4 Installation du dispositif doit être complété par un expert d installation certifié ou professionnel de CVC 5 Pour un usage résidentiel seulem...

Page 12: ... le moteur de la hotte est éteint Votre hotte Faber va fonctionner efficacement car il ya un nombre suffisant d air frais à tirer Est ce que ma fournaise ou un chauffe eau pénétrer air de combustion de ce système Non seulement ce système permet de compenser l air qui est évacué par la hotte Comment Puis Je savoir si j ai besoin d air d appoint Aujourd hui nouvellement construit des maisons ont une...

Reviews: