background image

                                                                                                                                              

4 < 

<

 

<

 

<

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ash bin 

Furnace chamber 

door  

Storage  

Flue 

connection  

Summary of Contents for Oscar

Page 1: ...Oscar 40011236 1143 Installation manual ENG ENG...

Page 2: ...coal briquette see user instructions Never use liquid igniters Use special ignition materials or wood wool for the kindling of the fire Never use wastes fine wooden chips mulch coal debris particle bo...

Page 3: ...ng air connections to other rooms with air openings at least 150 cm2 Ensure to keep proper lateral and rear distances from combustible parts and materials The associated values are specified in these...

Page 4: ...4 L Ash bin Furnace chamber door Storage Flue connection...

Page 5: ...ting value appr KJ kg Hard wood 19 500 Soft wood 14 600 Brown coal 11 500 3 1 Table 1 Filling quantities Split billet max Length 35 cm max 2 billet per filling appr 1 7 kg Brown coal briquette max 1 7...

Page 6: ...wise problems with draught can occur at other equipment leading to the same chimney Warning When opening the furnace chamber door any incorrect handling or insufficient draught may induce smoke Always...

Page 7: ...tchen paper tissues It provides an invisible film on the valuable surface of the Robax glass This film helps to keep the glass clean and facilitates regular cleaning operations ROBAX S for slightly co...

Page 8: ...r chimney and also that the doors of other fire places leading to the same chimney are closed and sealed properly Make sure that the chimney cleaning joints are sealed properly Too long and leaky smok...

Page 9: ...opening air connections to other rooms with air openings at least 150 cm2 4 2 Distances All the combustible materials furniture or e g decoration materials that are in the close environment of the fir...

Page 10: ...ustible materials in the building Provided that the interconnecting pieces have a non combustible coating of minimum 2 cm the distance from combustible materials may be at least 10 cm If the interconn...

Page 11: ...11 L Correct Incorrect...

Page 12: ...ith a stop cock close to the stove Of course heating is also possible with the air of the room see Item 2 2 Germany The stoves use room air for combustion and a sufficient supply of combustion air is...

Page 13: ...scar Nominal performance 8 Kw Heating capacity m3 under favourable less favourable not favourable heating circumstances according to 18893 TAB2 DIN standard 182 105 71 Flue gas values fuel Flue gas st...

Page 14: ...ctives and the following standards is hereby certified EN 13240 2005 ppa Munich 20 07 2009 Proper binding signature This Declaration certified compliance with the above referenced directives yet canno...

Page 15: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...

Reviews: