INSTALL THE RANGEHOOD
1.
Remove the unit from the carton and place on a flat
surface for assembly. Cover the surface to prevent
accidental damage. Remove all parts including the
mounting hardware before discarding the carton.
2.
Remove the grease filters USING TWO HANDS (one
to hold the filter so that it doesn't fall on cooktop and one
to turn the knob) by pulling the knob out and turning to the
left.
3.
The rangehood is shipped from the factory in the up
vent position as indicated in FIGURE 9. For top vent
applications, no additional adjustments are necessary.
Version 12/02 - Page 6
FIGURE 9
For rear vent applications, the blower must be turned
inside the rangehood so that the blower vents to the rear as
indicated in FIGURE 10. The blower is turned by removing
two screws on each side of the blower, rotating the blower
with the exhaust opening facing the rear and then replace
the screws. The exhaust cover must be moved to block the
unused opening. The blower must be converted before
installing the rangehood.
FIGURE 11
FIGURE 10
4.
Remove the cover from the field wiring compartment.
Remove the wiring electrical knockout using a flat-blade
screwdriver. Feed the Power Supply Cable through the
electrical knockout.
5.
The canopy attaches to the wall by two screws
discussed earlier in the installation instructions. The
canopy hangs from these screws by brackets inside the
rangehood shown in FIGURE 11. Before attempting to
hang the canopy, you should rotate the adjustment screw
marked V1 in FIGURE 11 counterclockwise to extend the
brackets from the canopy. Using a Phillips head
screwdriver, rotate this screw counterclockwise to extend
the bracket.
6.
Install the damper before hanging the rangehood.
The damper attaches to the rangehood by two small
screws provided in the hardware package. If 48" hood is
to be connected to 10" round duct, install the Duct
Transition Kit now.
7.
Hang the rangehood canopy from the screws. Due to
the weight of the canopy, these screws must be installed
into solid material! Once the canopy is hung, rotate the
screw marked V1 to secure the rangehood to the wall.
MAKE SURE THAT THE RANGEHOOD IS SECURELY
ATTACHED TO THE WALL! FAILURE TO PROPERLY
INSTALL COULD RESULT IN INJURY OR DAMAGE TO
PROPERTY.
8.
The brackets shown in FIGURE 11 are also used to
adjust the level of the canopy. Using a Phillips screwdriver,
rotate the screw V2 to adjust the level of the canopy.
9.
Connect the Power Supply Cable to the rangehood.
Attach the White lead of the power supply to the White lead
of the rangehood with a twist-on type wire connector.
Attach the Black lead of the power supply to the Black lead
of the rangehood with a twist-on type wire connector.
Connect the Green ( Green and Yellow ) ground wire under
the Green grounding screw.
10.
Replace the field wiring compartment cover and the
grease filters.
11.
If the installation uses a telescopic chimney, connect
the ductwork and install the chimney. Mount the upper
chimney section to the wall first. Then mount the lower
section. The lower section fits over the upper section.
If the installation uses a full width duct cover, install it now.
12.
Turn the power supply on. Turn on blower and light.
The rangehood controls are located on the right-hand side
under the canopy. If the rangehood does not operate,
check that the circuit breaker is not tripped or the house
fuse blown. If the unit still does not operate, disconnect the
power supply and check that the wiring connections have
been made properly.