background image

 

User manual Symax

 

6 < 

<

 

<

 

<

 

 

Switch the step burner 

For fires with step burner only! 
 

 

Please note! 
The step burner will not operate for 45 
seconds after the start-up procedure. 
 

 

Press the   key until   
appears in the display screen 
and the flame picture will be 
concentrated in the middle of 
front of the burner. 

 

Press the   key until   
disappears in the display 
screen and the flame picture 
will divide over the complete 
length of the burner. 

 
At the next start, the fire will start in the last 
selected position. 
 

 

Switch the LED Symbio effect 

 

 

Please note! 
This function is only for fires equipped with a 
LED Symbio effect. 

 
The Led Symbio module is independent of the 
flames and is equipped with a standard light 
pattern. 

 
Turn on 
Press the   key until   
appears in the display screen. 
 
Turn off 
Press the   key until   
disappears in the display 
screen 

 
Adjusting the light effect 
The light effect can be adjusted in 6 LED modes: 

 

 

Press the   key until   
flashes. 

 

Press the   or the   key to 
get to the desired light effect. 

 

To confirm, press the   key or 
wait. 

 
Now, the light effect is adjusted! 

 
 
 
 
 
 

 

Extended functions 

 

 

Countdown timer 

 

 

Please note! 

 

The countdown timer works in 
Manual and Thermostatic mode only. 

 

Max countdown time is 9 hours and 
50 minutes. 

 

At the end of the countdown time the 
fire turns automatically off. 

 
Set and turn on 

 

Press the   key until   
appears in the display screen 
and the hour indication will 
blink. 

 

Press the   or   key to set 
the hour. 

 

To confirm press the   key 
and the minute indication will 
blink. 

 

Press the   or   key to set the minutes. 

 

To confirm and start, press the   key or 
wait a few seconds. 

 
Turn off 
Press the   key until   disappears in the display 
screen. 

 

 

Thermostatic mode 

 

 

Please note! 
For a proper functioning of the Thermostatic 
mode, it is necessary that the remote control 
is installed in the wall bracket in the 
prescribed location (see section 3.1). 

 
The room temperature is measured and compared 
to the selected temperature. The flame height is 
then automatically adjusted to achieve the 
selected temperature. 
 
Set 

 

Press the   key until   
appears in the display screen 
and the temperature 
indication flashes.  

 

Press the   or   key to set 
the temperature. 

 

To confirm and start press the 

 key, or wait a few seconds. 

 

 

Summary of Contents for Symax

Page 1: ...User manual Symax Mertik ENG 40011927 1939 ...

Page 2: ...al number This user manual is intended for the following gas fires MatriX 450 500 I II III MatriX 450 650 I II III MatriX 800 500 I II III MatriX 800 650 I II III MatriX 1050 500 I II III MatriX 1050 650 I II III Blokhus Respect Premium OC ...

Page 3: ...User manual Symax 2 1 1 1 2 1 3 1 4 1 5 1 6 2 0 ...

Page 4: ...ced around the fireplace As a fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials and carpeted floors are included in this air circulation These parts can settle as soot on cold surfaces The moment using the fire for the first time depends on various circumstances Consult your in...

Page 5: ...pair them again Remote control The battery indication in top right corner of the display screen indicates the status of the batteries fig 2 0 After replacing the batteries the settings of the Thermostatic and Program mode have been reset to the factory settings Section 6 2 and 6 3 Placing batteries in the remote control Slide the battery cover of the remote control fig 1 2 Place 2 AA 1 5 Volt Alka...

Page 6: ...wo key operation Standard is one key operation To set this immediately press the key for 10 seconds after placing the batteries and wait until 1 or 2 flashes Release the key when the desired number of flashes appear Basic functions Switching ON One key operation Press the key until two short beeps and blinking series of lines appears The fire automatically starts on high setting Fires equipped wit...

Page 7: ...onfirm press the key or wait Now the light effect is adjusted Extended functions Countdown timer Please note The countdown timer works in Manual and Thermostatic mode only Max countdown time is 9 hours and 50 minutes At the end of the countdown time the fire turns automatically off Set and turn on Press the key until appears in the display screen and the hour indication will blink Press the or key...

Page 8: ...he key until OFF appears and the temperature flashes Press the or key to set the switch off temperature To confirm press the key Set day ALL flashes Press the or key to set the right day or period To confirm press the key Set ON time Program 1 1 and ON appears in the display screen and the hour flashes Press the or key to set the switch on hour Press the key to confirm and the minutes flashes Pres...

Page 9: ...past the ON position fig 1 6 This causes a rattling sound Please note When step burner you can t switch between narrow and wide manually Fault codes remote control Fault code Duration time fault code on display Symptom Possible cause F04 4 sec No pilot flame within 30 sec Attention After 3 failed ignition attempts error code F06 appears No gas supply Air in burner pipe pilot flame No spark Reverse...

Page 10: ...User manual Symax 9 ...

Page 11: ...User manual Symax 10 ...

Page 12: ......