17
<
<
<
<
UK
IRL
Handing over (final check and customer briefing)
•
Instruct the customer on the full operation of the appliance and the remote
control, including replacement of batteries
•
Advise the customer how to clean the appliance including the glass
•
Hand over these instructions including the user guide to the consumer
•
Recommend that the appliance should be serviced by a competent person at least
once a year
7
Servicing
To ensure safety, efficient operation of the appliance, it is necessary to carry out routine
servicing at regular intervals. It is recommended, that the fire is inspected/serviced by a
competent person at least once a year.
Important
Turn off the gas supply before commencing any servicing. Always test for gas soundness
after refitting the appliance. The flue should be checked when “Work” is carried out on
the appliance.
Check if the appliance is installed with a debris cap. In case the appliance is installed with
a debris cap, remove the whole firebox for examination of debris and check the chimney.
7.1
Routine annual servicing
Clean if necessary:
•
the pilot system
•
the burner
•
the combustion chamber
•
the glass
•
Check the log lay and replace the embers (if applicable).
•
Do the functional test as described at 6.2.
•
Check the flue system and do a spillage test as described at 6.3.
Note
Never place extra elements of any kind into the combustion chamber.
To guarantee good combustion, the log set may only be installed in the way specified by
Faber International. Any other arrangement can lead to soot on logs or window. Do not use
the fire with broken or missing logs.