21
<
<
<
<
UK
IRL
9
Technical specifications
Country
UK/IRL
UK/IRL
Cat.
II2H3+
II2H3+
Timra/Vista
Timra/Vista
Appliance type
B11BS
B11BS
Reference gas
G20
G31
Input (nett)
[kW]
5
4,6
Efficiency class
2
2
Inlet pressure
[mbar] 20
37
Gas Rate (15º C en 1013 mbar)
[m3/h] 0,53
0,19
Setting pressure
[mbar] 12
20
Injector size
[mm]
3x1,2
3x0,8
reduced input restrictor
[mm]
1,6
1,0
Pilot assembly
Type
SIT 160
SIT 160
code
Nr 51
Nr 30
Flue size (min)
100mm/125mm
100mm/125mm
Min Flue height
3 m
3 m
Gas control
GV36-C5AOEHC68M
GV36-C5AODHC68M
Remote control
adapter
230VAC/50HZ/5VA
230VAC/50HZ/5VA
Voltage adapter
4,5
4,5
Batteries remote control
2 x LR03 Alkaline
long live
2 x LR03 Alkaline
long live
Gas connection
8mm nut and olive
8mm nut and olive
Dimensions: see table 1