INSTALLATION

 

Drilling the Wall 

If the hood is to be connected in the ducting version, with the pipe coming out of the back, re-
member that the air venting duct must be created as indicated in the drawing. 
 

0

0

 

 
If the hood is fitted in the recirculation version, bear in mind that there must be a minimum dis-
tance of at least 8-10 Cm left between the top of the hood and the surface above it (ceiling or 
shelf). 

Draw the following on the Wall: 
•  a Vertical line up to the ceiling or top surface, at the centre of the area in which the Hood is 

to be fitted; 

•  a Horizontal line: 550 mm min. above the Hob; 
•  As shown in the drawing, mark a reference point 720 mm above the reference horizontal 

line, and at a distance of 155 mm to the right of the vertical reference line. 

•  Repeat this operation on the other side, checking to ensure it is level. 
•  Drill the points marked using a ø 12 mm drill bit. 
•  Insert the wall plugs with screw and bracket 

11a

 into the holes, tighten. 

•  As shown in the drawing, mark a reference point 196.5 mm above the reference horizontal 

line, and at a distance of 165 mm to the right of the vertical reference line. 

•  Repeat this operation on the other side, checking to ensure it is level. 
•  Drill the points marked using a ø 8 mm drill bit. 
•  Insert the plugs 

11

 into the holes. 

  

 

Rear air outlet 

area

 

Summary of Contents for Titano

Page 1: ...INSTRUCTIONS MANUAL EN TITANO...

Page 2: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 3: ...Controls Light Suction Unit Filters Lower Duct 7 1 PVC Pipe fitted 8 1 Inclinable grid fitted 9 1 Reduction flange 150 120 mm 10 1 Metal cover Ref Q ty Assembly components 11 2 Wall Plugs 11a 2 SB 12...

Page 4: ...EN 5 5 Dimensions...

Page 5: ...e fitted a Horizontal line 550 mm min above the Hob As shown in the drawing mark a reference point 720 mm above the reference horizontal line and at a distance of 155 mm to the right of the vertical r...

Page 6: ...ing diameter is 150 REAR AIR OUTLET When drilling the air outlet hole in the wall proceed in accor dance with the scheme in the part concerning the wall drilling Use a pair of tongs when breaking the...

Page 7: ...rid 8 on the air outlet Make sure that the position of the grid is correct Make sure that charcoal filters have been placed inside the hood 8 7 ELECTRICAL CONNECTION Connect the hood to the mains thro...

Page 8: ...le to change the operating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 second...

Page 9: ...r Recirculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVA...

Reviews: