9
FIXING THE PLATE
• Lift up the fixing plate, taking care to ensure that
the limit pawl is positioned frontally.
• Fit the slots onto the two screws previously in-
serted in the ceiling, and turn until they are at the
centre of the adjustment slot.
• Tighten the two screws completely and screw in
the other two provided; before locking the screws
completely it is possible to make adjustments by
turning the piece, making sure that the screws do
not come out of the adjustment slot.
• The unit must be securely fastened both due to
the weight of the Hood and the stress caused by
occasional sideways pressure on the Appliance
when in position. Once the unit has been fixed,
make sure that the plate is stable.
• In all cases where the Ceiling is not sufficiently
strong at the point of suspension, the Installation
technician must strengthen it with suitable plates
and counterplates, anchored to structurally sound
elements.