FabiaTech Corporation
54
Serial Ports
The ACEs (Asynchronous Communication Elements ACE1 to ACE2) are used to
convert parallel data to a serial format on the transmit side and convert serial data
to parallel on the receiver side. The serial format, in order of transmission and
reception, is a start bit, followed by five to eight data bits, a parity bit (if
programmed) and one, one and half (five-bit format only) or two stop bits. The
ACEs are capable of handling divisors of 1 to 65535, and produce a 16x clock for
driving the internal transmitter logic.
Provisions are also included to use this 16x clock to drive the receiver logic. Also
included in the ACE a completed MODEM control capability, and a processor
interrupt system that may be software tailored to the computing time required to
handle the communications link.
The following table is a summary of each ACE accessible register
DLAB
Port Address
Register
Receiver buffer (read)
0
Base + 0
Transmitter holding register (write)
0
Base + 1
Interrupt enable
X
Base + 2
Interrupt identification (read only)
X
Base + 3
Line control
X
Base + 4
MODEM control
X
Base + 5
Line status
X
Base + 6
MODEM status
X
Base + 7
Scratched register
1
Base + 0
Divisor latch (least significant byte)
1
Base + 1
Divisor latch (most significant byte)
Receiver Buffer Register (RBR)
Bit 0-7: Received data byte (Read Only)
Transmitter Holding Register (THR)
Bit 0-7: Transmitter holding data byte (Write Only)
Interrupt Enable Register (IER)
Bit 0: Enable Received Data Available Interrupt (ERBFI)
Summary of Contents for Fanless Series FX5403
Page 6: ...vi Appendix 59 Dimension 59 ...
Page 7: ...vii ...
Page 10: ...FabiaTech Corporation 3 Layout 1 2 Antenna 4 2 3 1 DC12 24V ON OFF ...
Page 13: ...FabiaTech Corporation 6 ...
Page 23: ...FabiaTech Corporation 16 ...
Page 51: ...FabiaTech Corporation 44 ...