Each pack of tubes has its own instruction leaflet but the following notes should help you take
readings after the tests have been completed.
Each tube has an expiry date which is located on the back of its storage box.
Oil (6728371) -
REQUIREMENT
- FOR BREATHING-AIR STANDARD EN12021 THE AIR SHOULD HAVE A
MAXIMUM OIL CONTENT OF 0.5 MG/M³ AND SHOULD BE WITHOUT
SIGNIFICANT ODOUR OR TASTE.
FOR HTM02-01 THE AIR SHOULD HAVE A MAXIMUM OIL CONTENT OF
0.1 MG/M
3
Ensure the oil tube is kept vertical throughout this process.
Satisfactory test: - The white crystals will turn translucent and show at worst a slight discoloration.
Failed test:
- (Mineral oil) - The white crystals will show a light brown or darker
discoloration.
- (Synthetic oil) - The white crystals will show a yellow discoloration [Note: best
seen by comparing with an unused tube].
Disposal of Dräger-Tubes
When Dräger tubes have been used, or unopened tubes have exceeded their expiry date, they should
be disposed of using one of the following methods:
Used Tubes Submerge the tube(s) in a beaker or metal container filled with water and allow to
soak for 24 hours. Treat the residual water in accordance with local authority waste regulations (some
tube aqueous waste may require neutralisation prior to disposal). Place the tubes in a “sharps” or
glass bin wearing protective gloves and safety spectacles. Dispose of the bin via the company’s
normal industrial waste disposal method(s) i.e. landfill or incineration.
OR Place the tubes in a “sharps” or glass bin wearing protective gloves and safety spectacles.
Dispose of the bin via the company’s normal hazardous waste disposal method(s) i.e. landfill or
incineration.
Unused Tubes Open the Dräger tube at both ends using the special tube opener or the cutter on
the hand pump. Break any ampoules where applicable. Dispose of the tubes as stated in Methods 1,
2 or 3.
NOTE: As an alternative a local authority approved waste disposal contractor can be employed to
collect used and unused tubes from site and dispose of them in a safe manner.