PRODUCT FEATURES
ON/OFF SAFETY PILOT VALVE KIT WITH PROPANE/LP CONVERSION
An optional on/off valve/safety pilot kit with a piezo ignitor is available for this appliance. This
system requires no matches, batteries, or other sources to light. You must use this optional
system for Propane/LP conversion.
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of
The National Fuel
Gas Code, ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
LOCAL CODES
State of Massachusetts:
The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas
-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.
Minimum Free Opening Area of Chimney Damper
for Venting (sq. in.) For Factory-Built Fireplaces
Chimney Height
14"
18"
24"
15' (Min)
41
47
53
20'
37
43
48
30'
33
38
43
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
Natural Gas
Minimum 5.5" W.C. Maximum 10.5" W.C.
Propane/LP Gas*
Minimum 11" W.C. Maximum 11" W.C.
* For use if unit is converted to Propane/LP gas.
SPECIFICATIONS
Model
FGB14-1
FGB18-1
FGB24-1
Gas Type
Natural
Natural
Natural
BTU Input*
45,000 BTU/Hr
55,000 BTU/Hr
65,000 BTU/Hr
Minimum Vent Opening
8" Diameter
8" Diameter
8" Diameter
Burner Orifice (Propane/LP)**
205 (mm)
225 (mm)
242 (mm)
* Btu/Hr Rating is the same when unit is converted to Propane/LP gas.
** Number is printed on orifice. Located in NVDWA2 kit when converting to LP gas.