www.factorybuysdirect.com
9
200254-01A
INSTALLATION
CONNECTION TO GAS SUPPLY
WARNING: A qualified ser-
vice person must connect ap-
pliance to gas supply. Follow all
local codes.
Installation Items Needed
Before installing appliance, make sure you
have the items listed below.
• piping (check local codes)
• sealant (resistant to natural gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
CAUTION: Only use a new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to appliance.
If pipe is too small, loss of pres-
sure will occur.
Installation must include an equipment shut
-
off valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
appliance (see Figure 8).
IMPORTANT:
Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Apply pipe joint sealant lightly to male threads.
This will prevent excess sealant from going
into pipe. Excess sealant in pipe could result
in a clogged burner injector.
Install sediment trap in supply line as shown
in Figure 8. Locate sediment trap where it is
within reach for cleaning. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into appliance controls. If sediment trap is not
installed or is installed incorrectly, appliance
may not run properly.
Figure 8 - Gas Connection
Approved Flexible Gas Hose
(if allowed by local codes)
CSA Design - Certified
Equipment Shutoff Valve
with 1/8" NPT Tap*
3" Minimum
From Gas Meter
(5" W. C.**
to 10.5" W. C.)
pressure
Sediment Trap
Cap Pipe Tee
Nipple Joint
* Purchase the optional CSA design-certified
equipment shutoff valve from dealer. See
Accessories
page 19.
** Minimum inlet pressure for purpose of input
adjustment.