- 36 -
FC-
WALK-BEHIND-V2
-OP-EN
Error
Internal Label
Code
Type
Description
Action
Remedy
HARD_FAULT
0
Flag used to define a show-stop-
per failure requiring a power
cycle
SOFT_FAULT
1
Flag used to define an error that
may disable a device but keep the
rest of the machine operational
NO_ERROR
0
Used internally
Bad Personality
BAD_PERSONALITY
10
hard/soft Incompatable options pro-
grammed or a checksum failure
The machine is disabled or
continues operating with
factory default parameters
Check programming
options and/or reprogram
EEPROM
Initial throttle
fault
INITIAL_THROTTLE_FAULT
11
soft
Throttle is engaged at power up
preventing a successful return to
idle state
Machine remains in a
pre-idle condition until the
active throttle condition
goes away
Take your foot off the gas
SHORT_CIRCUIT
12
hard
Memory fault
EEPROM_READ_ERROR
13
hard/soft An error was detected during an
EEPROM read access
The machine is disabled or
continues operating with
factory default parameters
Cycle keyswitch. If
problem persists change
control board
Dead battery
LOW_BATTERY_PROTECT
14
hard
The battery voltage has dropped
below NN.n Volts
The machine is disabled
Charge or replace batteries
Low battery
charge
LOW_BATTERY_CHARGE
15
soft
The battery voltage has dropped
below NN.n Volts and all but
the transport motor have been
disabled
All but the transport motor
are disabled is disabled
Charge battery
Overheat CPU
THERMAL_CUTBACK_MCU
16
hard
The microcontroller hardware has
had an over temperature failure
The controller is switched
off
Keyswitch off, wait ten
minutes, keyswitch on. If
problem persists change
control board
PRECHARGE_FAILURE_TRA
17
Transport idle
current fault
TRACT_LEFT_NULL_ERROR
18
hard
An abnormally high idle current
has been detected in the trans-
port motor (operational motor)
The machine is disabled
Brush idle
current fault
BRUSH_NULL_ERROR
19
soft
An abnormally high idle current
has been detected in the brush
motor (operational motor)
Brush, deck actuator and
water/suds are disabled
Vacuum idle
current fault
VACUUM_NULL_ERROR
20
soft
An abnormally high idle current
has been detected in the vacuum
motor (operational motor)
Vacuum motor is disabled
Squeegee idle
current fault
SQUEEGEE_NULL_ERROR
21
soft
An abnormally high idle current
has been detected in the squee-
gee motor (operational motor)
Squeegee motor is disabled
BRU_ADJ_OUT_OF_RANGE
22
soft
Transport motor
relay not open
SOLENOID_WELDED_TRA
23
hard
The main traction relay was
detected closed during power on
The machine is disabled
Keyswitch off, wait ten
seconds, keyswitch on. If
problem persists change
control board
Transport motor
relay not closed
SOLENOID_DIDNT_CLOSE_TRA
24
hard
The main traction relay was de-
tected open after being energized
during power on
The machine is disabled
Throttle fault
THROTTLE_FAULT
25
hard
An illegal voltage has been read
from the throttle feedback circuit
The machine is disabled
Check throttle action and
voltages
TOUCH SCREEN ERROR CODES
Summary of Contents for Micro-HD V2.0
Page 15: ...FC WALK BEHIND V2 OP EN 15 1 2 2 1 INSTALL SQUEEGEE 3 3 4 4 5...
Page 16: ...16 FC WALK BEHIND V2 OP EN 1 2 2 1 ADJUST SQUEEGEE RH LH 5 16 1 2...
Page 24: ...24 FC WALK BEHIND V2 OP EN FLUSHING RECOVERY TANK 1 2...
Page 25: ...FC WALK BEHIND V2 OP EN 25 CLEAN DRAIN SAVER 1 2 3...
Page 26: ...26 FC WALK BEHIND V2 OP EN CLEAN CYLINDRICAL HOPPER 2 1...
Page 27: ...FC WALK BEHIND V2 OP EN 27 CLEAN VAC BOX SYSTEM 1 1 3 4 3 4 2 5 6 7 8...
Page 28: ...28 FC WALK BEHIND V2 OP EN REMOVE DISK BRUSHES 1 1 2 Rotate after 25 hrs Right Left...
Page 29: ...FC WALK BEHIND V2 OP EN 29 REMOVE CYLINDRICAL BRUSHES 1 2 Rotate after 25 hrs...
Page 39: ...FC WALK BEHIND V2 OP EN 39 MILITARY GRADE SCHEMATIC...
Page 40: ...40 FC WALK BEHIND V2 OP EN BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 41: ...FC WALK BEHIND V2 OP EN 41 TOUCH SCREEN SCHEMATICS...
Page 42: ...42 FC WALK BEHIND V2 OP EN BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 43: ...FC WALK BEHIND V2 OP EN 43 LEGACY SCHEMATIC...
Page 44: ...44 FC WALK BEHIND V2 OP EN BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 45: ...FC WALK BEHIND V2 OP EN 45 BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...