background image

7

PIC. 13

VALVE COVER

THRUST ADJUSTMENT:
DO THIS OPERATION
WITH BOTH UNITS

MORE THRUST/PUSHING POWER

LESS THRUST/PUSHING POWER

RED

RED

BLUE

YELLOW/GREEN

HYDRAULIC RELEASE - LEVER S

TO RELEASE THE UNIT TURN THE LEVER S
WHICH IS FITTED ON THE HYDRAULIC MOTOR PUMP

LEFT-HANDED

RED

RED

BLUE

YELLOW/GREEN

VALVE COVER

MORE THRUST/PUSHING
POWER

LESS THRUST/PUSHING
POWER

GATE STOP

GATE STOP

GATE HOLDING
LATCH

95

°

90

°

GATE

GATE

LOCK KEY

LH

RH

70 cm

PIC. 12

PIC. 14

LID

745

®

Anti-crush safety is ensured by the pressure valves which allow for a very fine adjustment of the required pushing power depending on
the gate size and weight; after setting no further adjustment is required thanks to their precise design. Also they are adequately protected
to prevent misuse. See pictures No. 12-13.

With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements. Double
gates can be fitted with an electric lock at a height as indicated in the picture and with a mechanical latch for a better hold of the gates
in the close position. See picture No. 14.

PLEASE NOTE: it is compulsory to fit gate stops in open gate position so that both gates stop 5

°

 before the end of the permitted piston

stroke.

The hydraulic jacks are designed right-handed and left-handed. Their correct application on the respective gate side will allow
the gates to move out of phase by 5 degrees. See the picture: the gate with the lock keep will reach the close gate stop position
earlier than the other one and will be ready to take the lock when the second gate reaches the closed position.

RIGHT-HANDED

RELEASE

LEVER

SB

GATE STOP.

5

°

MORE OPEN

THAN THE OTHER GATE

Summary of Contents for COMBI 740

Page 1: ...B Instruction manual COMBI 740 Oil hydraulic operator for swinging gates Below ground Version with two way locking device Version with brake in open close cycles Version with 110 and 175 shaft rotatio...

Page 2: ...RE VALVE CLOSE SAFETY PRESSURE VALVE OPEN VALVE COVER TWO WAY LOCKING VALVE ASSEMBLY MOTOR END PART MOTOR END PART PUMP SHAFT MOTOR BASE FLANGE SUCTION FILTER OIL RESERVOIR ELECTRIC MOTOR HYDRAULIC LO...

Page 3: ...IL RESERVOIR PLUG OIL RESERVOIR END CAP WIRE CONNECTORS HYDRAULIC OIL ARNICA A 15 BY AGIP ELECTRICAL CABLE RIGHT HAND JACK END CAP DAMPENING ADJUSTMENT ELBOW JOINT BEARING TOOTHED MAIN SHAFT CENTRAL B...

Page 4: ...6 LH 747 LH 746 RH 747 RH GATE SPACER HINGES NYLON WIRE It is recommended to keep to these instructions to install the equipment in the correct way to get a perfect working system Electro hydraulic op...

Page 5: ...close to the gate post dimensions as indicated in picture No 5 and lay the enclosure in it perfectly horizontal with the help of a level The upper edge of the enclosure must be levelled with the pavem...

Page 6: ...IN RELEASED POSITION OR NON LOCKING GATE FIXING PLATE WITH SHAFT FITTING COLLAR BOX SPANNER LONG BOLTS COMBI 740 SB RELEASE Once satisfied that everything has been done as described so far make sure...

Page 7: ...prevent misuse See pictures No 12 13 With single gates the electric lock is to be installed horizontally in the most suitable way to meet the application requirements Double gates can be fitted with a...

Page 8: ...AMPENING DAMPENING DEVICE OUT OF SERVICE IN SERVICE OIL FILLER CAP JUNCTION BOX CUT OUT BRICKWORK TO PROVIDE PROTECTION FOR THE CONTROL BOX Should the model with the dampening device be required to in...

Page 9: ...OR RUN OPEN CLOSE TIME CAPACITORS MICROPROCESSOR DIP SWITCH TERMINAL FOR CONNECTIONS TO PUSH BUTTONS PULIN 3 1 AMP FUSE 24 V OUTPUT TERMINALS 12 13 TIMER SWITCHES FUSE 630 mA FUSE 5 AMPS 1 st CHANNEL...

Page 10: ...Hz CONDENSER 12 5 F RED YELLOW GREEN BLUE RED CONNECT THE ENCLOSURE EARTH WIRE 2 1 3 10 PIC 21 PIC 20 SPECIAL VERSIONS FLOW REGULATORS FOR COMBI 740 MANUAL TEST FOR COMBI 740 ADJUSTMENT SCREW FLOW REG...

Page 11: ...HYDRAULIC PUMP Pump flow rate P3 0 85 l min Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Working temperature 20 C 80 C Rotation time 110 23 s Oil type A 15 FADINI by AGIP Shaft rotation a...

Page 12: ...TOTAL QUALITY CONTROL system which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of impro...