background image

16

electromechanical operator for swinging gates

DARDO 424

DARDO 424

Meccanica Fadini s.n.c.

Director in charge

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: 

Dardo 424

 complies 

with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original 
accessories and components as indicated by the manufacturing company.  An automatic gate operator is, by law, a “machinery” 
and therefore the installer must fit the equipment with all of the applicable safety norms. The installer is also required to issue 
the installer’s Declaration of Conformity.  The manufacturer is not liable for possible incorrect use of the product. The product 
complies with the following specific norms: analysis of the risks and subsequent action to cure them as per EN 12445 and
EN 12453,  Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 2014/30/UE. In order to certify the product, the 
manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT NORMS.
This product complies with the following norms:

CPD 89/106/CE 

DM 2006/42/CE 

BT 2006/45/CE 

EMC 2004/108/CE          R&TTE 99/5/CE.

English

GENERAL WARNINGS FOR PEOPLE SAFETY

INTRODUCTION 

This operator is designed for a specific scope of applications as 
indicated in this manual, including safety, control and signaling 
accessories as minimum required with 

FADINI

 equipment. 

 

Any applications not explicitly included in this manual may 
cause operation problems or damages to properties and 
people. 

 Meccanica Fadini snc is not liable for damages 

caused by the incorrect use of the equipment, or for 
applications not included in this manual or for malfunctioning 
resulting from the use of materials or accessories not 
recommended by the manufacturer. 

 The  manufacturer 

reserves the right to make changes to its products without 
prior notice. 

 All that is not explicitly indicated in this manual

is to be considered not allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 
of the access, its general condition and the structure. 

 Make 

sure that there is no risk of impact, crushing, shearing, 
conveying, cutting, entangling and lifting situations, which 
may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with flammable substances. 

 Keep all 

the accessories able to turn on the operator (transmitters, 
proximity readers, key-switches, etc) out of the reach of the 
children. 

 Transit through the access only with stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity of a working operator. 

 To ensure safety in the 

whole movement area of a gate it is advisable to install 
photocells, sensitive edges, magnetic loops and detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 
spots. 

 Before cleaning and maintenance operations, 

disconnect the appliance from the mains by switching off the 
master switch. 

 If removing the actuator, do not cut the 

electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.

INSTALLATION

All installation operations must be performed by a qualified 
technician, in observance of the Machinery Directive 
2006/42/CE and safety regulations EN 12453 - EN 12445. 

Verify the presence of a thermal-magnetic circuit breaker
0,03 A - 230 V - 50 Hz upstream the installation. 

 Use 

appropriate objects to test the correct functionality of the 
safety accessories, such as photocells, sensitive edges, etc. 

 

 

Carry out a risk analysis by means of appropriate instruments 
measuring the crushing and impact force of the main opening 
and closing edge in compliance with EN 12445. 

 Identify the 

appropriate solution necessary to eliminate and reduce such
risks. 

  In case where the gate to automate is equipped with a 

pedestrian entrance, it is appropriate to prepare the system in 
such a way to prohibit the operation of the engine when the 
pedestrian entrance is used. 

 Apply safety nameplates with CE 

marking on the gate warning about the presence of an 
automated installation. 

 The installer must inform and instruct 

the end user about the proper use of the system by releasing 
him a technical dossier, including: layout and components of 
the installation, risk analysis, verification of safety accessories, 
verification of impact forces and reporting of residual risks.

INFORMATION FOR END-USERS

The end-user is required to read carefully and to receive 
information concerning only the operation of the installation 
so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with the installer/maintenance technician (on -call). 

 Any 

maintenance operation must be done by qualified technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 
INSTALLATION

 

For optimum performance of system over time according to 
safety regulations, it is necessary to perform proper 
maintenance and monitoring of the entire installation: the 
automation, the electronic equipment and the cables 
connected to these. 

 The entire installation must be carried 

out by qualified technical personnel, filling in the Maintenance 
Manual indicated in the Safety Regulation Book (to be 
requested or downloaded from the site 
www.fadini.net/supporto/downloads). 

 Operator: maintenance inspection at least every 6 months, 

while for the electronic equipment and safety systems an 
inspection at least once every month is required. 

 The 

manufacturer, Meccanica Fadini snc, is not responsible for 
non-observance of good installation practice and incorrect 
maintenance of the installation.

DISPOSAL OF MATERIALS

Dispose properly of the packaging materials such as 
cardboard, nylon, polystyrene etc. through specializing 
companies (after verification of the regulations in force at the 
place of installation in the field of waste disposal). Disposal of 
electrical and electronic materials: to remove and dispose 
through specializing companies, as per Directive 2012/19/UE. 
Disposal of substances hazardous for the environment is
prohibited

.

Summary of Contents for Dardo 424

Page 1: ...EN 13241 EN 12453 EN 12445 DARDO 424 24 Vdc GB Instructions manual pages 15 28 15 the gate opener ...

Page 2: ...om the mains by switching off the master switch If removing the actuator do not cut the electric wires but disconnect them from the terminal box by loosening the screws inside the junction box INSTALLATION All installation operations must be performed by a qualified technician in observance of the Machinery Directive 2006 42 CE and safety regulations EN 12453 EN 12445 Verify the presence of a ther...

Page 3: ...are identified as Dardo M1 first gate to open and pedestriam mode and Dardo M2 gate delayed on opening Pic 3 Dardo does not come fitted with electronic limit switches as they are not necessary limit stop positions are learned by the system in phase of programming as determined by the incorporated stop plates Pic 1 displays all of the components that are delivered for the installation of each Dardo...

Page 4: ... equipment 7 Inspectable junction pit 8 Keyswitch or push buttons panel 4 x 0 5 mm 9 ELPRO 42 controller with VIX 53 1R plug in radio receiver card 10 Flasher with aerial 2 x 0 5 mm RG58 Type of cables to be used not included with the equipment Motor power supply safety and command accessories FROR CEI 20 20 CEI EN 50267 2 1 Aerial RG58 NOTE with distances longer than 50 m increase cable section a...

Page 5: ... open gate position do not use the open incorporated stop plate Installation distances considering the incorporated stop plates Installation distances considering the incorporated stop plates B B Pic 4 Pic 5 55 mm 55 mm D 60 90 90 A B C opening 90 130 130 600 90 mm 70 75 mm electromechanical operator for swinging gates DARDO 424 DARDO 424 English 19 A B C D A opening 0 90 120 D 90 610 max 90 openi...

Page 6: ...s 55 mm lower than the rear fixing to the gate post Pic 7 First fixing is the front one to the gate by using a strengthing plate according to C distance of Pic 4 or Pic 5 in the way as indicated in Pic 6 Pic 6 Strengthening patch plate not included Non metallic gates Get ready the rear fixing and fasten it to the gate post in respect of the installation geometry Pic 4 or Pic 5 and as indicated in ...

Page 7: ...l holes are provided to adjust the rear fixing in case A and B distances might be wrong Open the gate by hand and bring it close to the operator Swing this one on to the front bracket so that the fastening pin fits into the bush of the front fixing plate then tighten the locking screw avoid overtightening Locking screw IMPORTANT RECOMMENDED PUT SOME GREASE ON THE FASTENING PIN IMPORTANT IT IS RECO...

Page 8: ... hard Loosen the screw and adjust the position of the stop assembly inner and outer plates to touch the gate front fixing The plates must mesh the respective toothed bars into a firm block Tighten the screw hard Gate fixing Gate leaf fully open Gate leaf fully closed 2 1 Gate fixing 180 half a turn FADINI 4 FADINI FA DINI FADINI 3 FADINI FADINI electromechanical operator for swinging gates DARDO 4...

Page 9: ... open and in pedestrian mode if selected M2 Dardo on the gate leaf delayed in opening IMPORTANT on single gate installations where only one operator is mounted it is sufficient to connect the motor to M1 and bridge B1 with B2 while A2 and C2 terminals are not connected Dardo M2 Dardo M1 Terminal block for electrical connections A A B B C C A2 B2 C2 A1 A B C B1 C1 Dardo M2 power supply Dardo M1 pow...

Page 10: ...NG OUTWARDS ELPRO 42 Dardo M2 Dardo M1 A B C A B C A2 B2 C2 A1 B1 C1 Dardo M2 power supply Dardo M1 power supply Dardo terminals Dardo terminals electromechanical operator for swinging gates DARDO 424 DARDO 424 English Pic 16 24 ...

Page 11: ...e gate hinges and pivots be periodically lubricated as well Remove any possible obstacles and hindrances the gates must be able to move freely in open and close directions Pic 17 Pic 18 Ceck that photocells are free from obstacles or disturbance Re align if necessary Gate fixing pivot On the inner rolled screw shaft Gate post fixing pivot electromechanical operator for swinging gates DARDO 424 DAR...

Page 12: ...ator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors o...

Page 13: ...electromechanical operator for swinging gates DARDO 424 DARDO 424 English 27 ...

Page 14: ...50 C C opening closing times depend on the installation distances speed adjustment and gate inertia travel 320 stop centers travel 380 maximum 745 with stop plates fitted 770 without stop plates 160 150 55 106 832 100 120 100 110 90 100 68 30 30 106 70 electromechanical operator for swinging gates DARDO 424 DARDO 424 Via Mantova 177 A 37053 Cerea VR Italy Ph 39 0442 330422 Fax 39 0442 331054 info ...