GB
~ 70 cm
~ 70 cm
Gravel layer to provide
a soak-away system
600
ø 10 n° 8 pcs.
~ 70x70 cm
foundation plinth
Concrete foundation
Gravel layer
for water drainage
~ 100 cm
~ 100 cm
SECTION VIEW OF THE PLINTH
GASPO 252
- semiautomatic - with gas springs
Fixing plates
to cement
M10x30 TEI screws
0.0
Drwg. No.
6450
FITTING OPERATIONS
INSTRUCTIONS
GASPO 252
Fix the anchoring plates to the ground housing cylinder by the provided bolts, then provide a suitable foundation plinth made of
reinforced concrete around it, according to the rule of the art and following the dimensions indicated in the drawing. The reinforced
metallic structure (not supplied by the manufacturer) is to be positioned around the ground housing cylinder very close to it
in a
way that the anchoring plates be incorporated. The ground housing cylinder must be flat with the ground level.
Ground housing cylinder
Gaspo 252
Metallic framework to be
provided as a reinforcement
to set in the concrete
foundation around the
ground housing cylinder
Ground housing cylinder Gaspo 252
Metallic framework to be
provided as a reinforcement
to set in the concrete
foundation around the ground
housing cylinder