Drwg. No.
6450
GB
GASPO 252
- semiautomatic - with gas springs
INSTRUCTIONS
GASPO 252
OPERATIONS FOR ORDINARY ROUTINE MAINTENANCE OF FADINI SEMIAUTOMATIC BOLLARDS (EVERY SIX MONTHS)
The standard maintenance routine sequence is as follows:
• Clean the ground cylinder and remove dirt by a vacuum cleaner.
• Clean water drains located at the bottom of the ground cylinder and/or excavation pit.
• Check the screws fastening the bollard to the ground cylinder, making sure they are properly tightened and lubricated.
• Check the correct functioning of the gas springs (if any are fitted) and/or the levers system inside the bollard for unlocking and bollard removal
from its seat.
• Check the release system for bollard manual operations.
• Clean and recondition the rising cylinder if required, e.g.: paint patching up, replacing the retroreflecting approved sticker and /or the cover
fitted with rubber edge.
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualified and authorized technicians in
compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual.
3) Any application not indicated in this manual may cause malfunctioning or damage to people and properties.
4)
Providing a suitable reinforcement metallic framework ensures that the breakout resistance value be respected as stated in this manual.
NOTE
: the iron framework (all of the steel rebars) is not supplied by our company. It has to be made locally in compliance with the technical data,
drawings and all of the indications described in this installation manual. The components of the structure developed in this way are able to make
the most of the performance features of each component and ensure the impact resistance features of the bollard as indicated.
5) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
6) Make sure the site is free from utilities that may interfere with it.
7) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
8) The installer shall inform the final user of the dangers coming from the presence of persons, especially children, in the proximity of the
bollard.
9) The manufacturer reserves the right to change this manual without previous notice.
As far as configuration and execution of the system are concerned, these are to comply with the laws in the country of installation.
PRODUCT SPECIFICATIONS
Semiautomatic bollard, fully disappearing, consisting of two pushing gas springs inside the moving cylinder, operated by a specially designed
release spanner. Suitable for applications in private, commercial areas, and urban installations. The height of the moving cylinder (from ground)
is 500 mm. Moving cylinder made of S235JRH steel, thickness 4 mm and ø 200 mm, cataphoresis treated and powder coated. Assisted system for
bollard ascent, slowdown at end of stroke. Option in AISI 304 brushed stainless steel available. Rubber ring on moving cylinder head. Moving
cylinder fitted with high intensity, microprismatic, retroreflecting approved sticker (h 80 mm). Ground housing cylinder made of hot dip
galvanized steel, walkable and carriageable cover. Breakout resistance 160.000 J.
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under its own responsibility that
Gaspo 252
is in compliance with
the Machinery Directive 2006/42/CE, moreover: is to be sold and installed as a comprehensive “Automatic System”, including the accessories and
components as recommended by the Manufacturing Company. In observance of the current directives, any automation is to be regarded as a
“machine”. Therefore it is required that all the applicable safety norms are strictly complied with by the installation agents, who are also required
to issue a Declaration of Conformity. The manufacturing company is not liable for incorrect applications or misuse of its products that are
declared to be produced in compliance with the following norms: Analysis of the risk and actions to cure them EN 12445 & EN 12453, Low Voltage
Directive 2014/35/UE, Electro-magnetic Compatibility Directive 2014/30/UE. In order to certify the product the Manufacturer declares under his
own responsibility the compliance with the PRODUCT regulations under the NORMS EN 13241-1.
Meccanica Fadini s.n.c.
Responsible Manager
Meccanica Fadini is not liable for any possible damage derived from incorrect use or from any use not indicated in this manual,
furthermore it is not answerable for malfunctioning caused by the use of materials or accessories not approved by the company
itself. It is to be noted that the product respects the breakout resistance values as indicated provided that the installation of the
same is carried out in observance of the specifications included in this manual of instructions. Various factors are to be carefully
taken into consideration such as compaction index, soil permeability coefficient, concrete type, which may affect the indicated
values even significantly.
!