TECHNICAL SPECIFICATIONS

ELECTRIC MOTORS

Power output

Supply voltage

Frequency

Absorbed power

Absorbed current

Motor rotation speed

Capacitor

Intermittent service

Single-phase

0,37 kW (0,5 HP)

230 Vac

510 W

2,4 A

20 µF

Three-phase

0,37 kW (0,5 HP)

230/400 Vac

575 W

2,1/1,2 A

Single-phase

0,73 kW (1,0 HP)

230 Vac

50 Hz

1.130 W

5,7 A

1.380 rpm

30 µF

S3

Three-phase

0,73 kW (1,0 HP)

230/400 Vac

1.030 W

3,7/2,2 A

Three-phase

1,1 kW (1,5 HP)

230/400 Vac

1.500 W

5,1/3 A

OPERATOR

Rated torque

Gear rating

Travel speed

Working temperature

Oil type

Maximum gate weight

Horizontal Mec 200 weight

Vertical Mec 200 weight

Protection standard

Limit switch

PERFORMANCE

Frequency of use   

 

 

 

very intensive

Service cycle 

 

 

 

 

25 s opening - 30 s dwell - 25 s closing - 30 s dwell

Complete cycle time 

 

 

 

110 s

Complete opening - dwell - closing - dwell cycles 

No.33/hour

Annual cycles (with 8 hours of use per day) 

 

No. 96.000

Single-phase

40 Nm

1.200 kg

19,5 kg

19 kg

Three-phase

40 Nm

1.250 kg

18,5 kg

18 kg

Single-phase

80 Nm

1/32

10 m/1'

-25 °C +80 °C

Oil Fadini - Item 706L

1.800 kg

23,5 kg

23 kg

IP 55 (inside the cover)

mechanical

Three-phase

80 Nm

1.850 kg

21,5 kg

21 kg

Three-phase

110 Nm

2.000 kg

25,5 kg

25 kg

Mec 200 

vertical

Mec 200 

horizontal

OVERALL DIMENSIONS

FITTING ACCESSORIES FOR INSTALLING

Zinc-coated steel

base plate

260

200

120

Steel gear rack

22 x 22 mm thickness

2 m modules

Steel

gear rack fixing set

Limit switch striking

plates for screw fixing

to the gate

Power cut off

device

Steel gear rack

with fixing slots

1 m modules

Nylon gear rack

8 mm thickness

steel core

1 m modules

290 mm

160

130

285

225

92

467

92

172

40

Z18 m4

Side view

Front view

E 17 release spanner

130

174

245

467

290

92

130

160

60

38

Side view

Top view

Z18 m4

electro-mechanical sliding gate operator

2003/108/CE  Directive

Disposal of electric and

electronic equipment

DISPOSE PROPERLY OF MATERIALS

ARMFUL TO THE ENVIRONMENT

GB

2016/11

Via Mantova, 177/A - 37053 Cerea (VR) Italy 

Ph +39 0442 330422 

Fax +39 0442 331054

info

@

fadini.net   

www.fadini.net

Summary of Contents for MEC 200

Page 1: ... 12445 Electro mechanical sliding gate operator Vertical and horizontal installation Gear movements and worm gear coupling in oil bath fully mounted on ball bearings MEC 200 GB Instructions manual pages 1 8 the gate opener ...

Page 2: ...on The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and components of the installation risk analysis verification of safety accessories verification of impact forces and reporting of residual risks INFORMATION FOR END USERS The end user is required to read carefully and to receive information concerning onl...

Page 3: ... gate stops are fixed in the open and closed gate positions so that the gate does not over travel the permitted limit and go out of the upper guide make sure that a system be mounted to the gate to prevent it from falling over make sure that once at the end of the permitted travel the gate does not hit the gate posts or special gate stops to avoid damages to its structure FITTING MEC 200 ON TO THE...

Page 4: ...out friction pic 4 IMPORTANT before definitely fixing any component make sure that the rack can mesh the driving gear of Mec 200 so that the whole system gate included can be smoothly run by hand the full travel open and close without any friction Remove the 2 mm shims only after having fixed the rack An adequete clearance between rack and gear has thus been achieved pic 4 English Pic 3 Pic 4 MEC ...

Page 5: ...s the installer s responsibility to lay the connection pipes and tubes as properly and correctly required IMPORTANT all the electrical equipment to be properly earthed English MEC 200 Pic 5 Pic 6 15 mm LIMIT SWITCH STRIKING PLATE TO BE FIXED TO THE GATE BY BOLTS LIMIT SWITCH ROLLER FADINI 1 2 9 8 3 11 4 5 17 6 7 10 12 13 13 14 15 16 230 V n 2x1 n 2x1 n 4x1 n 4x1 cable RG58 n 4x1 5 n 4x1 5 n 4x1 n ...

Page 6: ...be adjusted to the gate weight Adjusting is by a screw which is located on one side of the operator A special spanner E17 is provided with the equipment for this purpose unscrew the locknut the more you tighten the screw clockwise the more you increase the operator torque by unscrewing it torque is decreased Once set it to meet the site requirements tighten the locknut hard pic 9 ELECTRIC MOTOR CO...

Page 7: ...el Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors officers an...

Page 8: ...e phase 40 Nm 1 200 kg 19 5 kg 19 kg Three phase 40 Nm 1 250 kg 18 5 kg 18 kg Single phase 80 Nm 1 32 10 m 1 25 C 80 C Oil Fadini Item 706L 1 800 kg 23 5 kg 23 kg IP 55 inside the cover mechanical Three phase 80 Nm 1 850 kg 21 5 kg 21 kg Three phase 110 Nm 2 000 kg 25 5 kg 25 kg Mec 200 vertical Mec 200 horizontal OVERALL DIMENSIONS FITTING ACCESSORIES FOR INSTALLING Zinc coated steel base plate 2...

Reviews: