VIGILO
VIGILO
8
!
Loop in
entry gateway
Loop in
entry gateway
Loop in
exit gateway
min 80 cm
Elpro S40
Fit 55
Fit 55
min 1,0 m
min 1,0 m
Fit 55
Fit 55
Visual 344
Ø 275
Chis 37
1.890 mm
Loop in
exit gateway
English
fully retractable oil-hydraulic bollard
Pic. 9
Pic. 7
Pic. 8
MAGNETIC LOOP PREPARATIONS
IMPORTANT:
make sure that no other electro-magnetic sources are located on or under the ground near the installation to
prevent interference or any affecting action with the magnetic loops of the vehicle detecting device if installed or
with any other electronic equipment included in the system for commanding and controlling operations.
The magnetic loop detector is a safety device operating all the time to detect any transiting vehicle: the bollard is prevented from
rising should a vehicle cross the loop.
A hole is to be dug in the ground as indicated (see relative instructions sheet). For proper and correct functioning of the loop
detector it is recommended to strictly keep to the installation geometry as indicated in the instructions.
VIGILO bollard
Power supply cable
10 meters max,
pre-fitted to the loops
Metal detector.
See instructions included
with the equipment
(optional in the catalogue)
• Pre-assembled loop
6 meters
across
(optional in the catalogue)
• Pre-assembled loop
12 meters
across
(optional in the catalogue)
ARRANGEMENT OF THE PHOTOCELLS
Electric cables laid in the ground in a corrugated sheath