background image

Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054 - e-mail: info@fadini.net - www.fadini.net

OVERALL DIMENSIONS

PIC. 14

510

845

1,35 m

Ø 200

410

410

170

Ø275

10

®

s.n.c.

CHECKING AND MAINTENANCE:

To achieve an optimum performance and longer life of the equipment and in observance of the safety regulations, it is recommended that inspections
and maintenance are made by qualified technicians to the whole installation ie. both the mechanical and electronic parts as well as wiring:
- Oil-hydraulic automation: maintenance every 6 months
- Electronic and safety equipment: maintenance monthly

AUTOMATIC GATE MANUFACTURERS

EUROPEAN MARK CERTIFYING CONFORMITY TO
THE ESSENTIAL REQUIREMENTS OF THE
STANDARDS 98/37/EC

Made in Italy

®

The manufacturers reserve the right to change the products without any previous notice

Distributor’s box

• DECLARATION OF CONFORMITY
• GENERAL WARNINGS
• EN 12453, EN 12445 STANDARDS
• WARRANTY CERTIFICATE ON THE CUSTOMER’S REQUEST

The growth of MECCANICA FADINI has always been based on the
development of guaranteed products thanks to our “TOTAL QUALITY
CONTROL” system which ensures constant quality standards, updated
knowledge of the European Standards and compliance with their
requirements, in view of an ever increasing process of improvement.

The “CE” mark certifies that the operator conforms to the essential
requirements of the European Directive art. 10 EEC 73/23, in relation to the
manufacturer’s declaration for the supplied items, in compliance with the
body of the regulations ISO 9000 = UNI EN 29000. Automation in conformity
to EN 12453, EN 12445 safety standard.

Bollard flush with ground level

Front view

Raised bollard

Front view

Raised bollard

Lateral view

Stroke 500 

mm

Cable length
10metres

Stroke 500 

mm

PUMP ASSEMBLY

Pump type  ..................................................................................................................P 10
Pump flow rate ................................................................................................4,45 

l

/min

Average working pressure ..................................................................2 MPa (20 bars)
Max. pump pressure ............................................................................4 MPa (40 bars)
Working temperature .................................................................................–20

°

C +80

°

C

Power oil type........................................................................OIL FADINI A 15 by AGIP
Pump assembly static weight ...............................................................................10 Kg
Pump ass. protection standards............................................................................IP 54

ELECTRIC MOTOR

Power rating........................................................................................0,25 KW (0,33 HP)
Supply voltage .........................................................................................................230 V
Absorbed current......................................................................................................1,8 A
Frequency..................................................................................................................50 Hz
Absorbed power .....................................................................................................330 W
Capacitor ...................................................................................................................20 

μ

F

Motor revolutions .........................................................................................2˙800 rev./1’
Service Standards .......................................................................................................S 3

HYDRAULIC PISTON

Piston stroke travel time........................................................................................4 sec.
Piston stroke.........................................................................................................500 mm
Shaft diametre........................................................................................................16 mm
Piston diametre ......................................................................................................30 mm
Max. pushing power Open ................................................................................280 daN
Protection standard complete ref........................................................................IP 557

PERFORMANCE

Duty cycle: ...........................................................4s Opening - 30s Dwell - 4s Closing
Time of one complete cycle ........................................................................38 seconds
Complete cycles Opening-Dwell-Closing................................................No. 95/hour
Cycles per year (8 hours'service per day)................................................No. 270˙000

Static weight Vigilo 2250 ....................................................................................102 Kg

TECHNICAL SPECIFICATIONS

9-2005

IGILO

  

2250

V

IGILO

  

2250

V

Summary of Contents for VIGILO 2250

Page 1: ...FITTING INSTRUCTIONS GB ...

Page 2: ...fter fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control the post starts rising A reflecting sticker makes it well visible and an optional flashing lamp or traffic lights ensure clear indication of the post movements or status An electronic control panel fitted with ...

Page 3: ...an be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from termination ENCLOSURE COVER PLATE HYDRAULIC MOTOR PUMP POST COVER EDGE PROTECTION RUBBER RING HOUSING CYLINDER AND PISTON ASSEMBLY CABLE OF THE OPEN LIMIT SWITCH LOWERED POST 10 METRE LENGTH ELECTRIC MOTOR CABLE 10 METRE LENGTH LIFTING EYE LIFTING MECHANISM RISING...

Page 4: ...ide of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Vigilo 2250 is to be located as indicated in Pic 5 Provision is made within the unit for the entry of a Ø 50 mm duct to the electronic control unit the cables are 10 m long Provide a soakaway by pouring shing...

Page 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch cables through the duct to the control unit Be careful not to damage or remove the cables from their termination Pic 7 Once satisfied that the guide tube assembly is properly fitted inside the locati...

Page 6: ...ld be connected as indicated in the diagram a 20μF capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20μF capacitor fitted inside Elpro 10 PLUS CEI Earth Limit switch cable Important Bridge the Common and Limit Switch Close terminals 8 and 9 Read the description of the electronic control unit Elpro 10 PLUS CEI on page 8 Pic...

Page 7: ... square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be used ESSENTIAL COMPONENTS OF THE INSTALLATION 1 Miri 4 flashing lamp with incorporated aerial 2 Prit 19 keyswitch 3 Polo 44 photo cell projector 4 Jubi 433 receiver in weather proof casing 5 Elpro 10 ...

Page 8: ...p while opening 2 ON Radio No reversing while opening 3 ON Automatic closing 4 ON Preflashing activated 5 ON Radio Step by step Stop in between 6 ON Dead Man Control Dip 4 OFF and Dip 3 OFF 7 ON No lamp on during dwell time 8 OFF No function T S R PULIN 3 26 27 28 3 DIP SWITCH ON OFF 1 4 5 6 7 8 2 3 L2 L3 L4 L5 L6 L7 L8 L9 1 7 4 10 11 12 13 19 20 2 8 5 3 9 6 STOP COMMON OPEN CLOSE 230V 25W max FLA...

Page 9: ...Automatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DIP SWITCH 3 ON Automatic Closing OFF No Automatic Semi automatic closing by pulse Automatic Semiautomatic Automatic Operation any pulse opens the gate the gate stays open as long as the Dwell time exp...

Page 10: ...US CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrical connections of the green red traffic lights Traffic lights Red Light 230V 25 60W Green Light 230V 25 60W Limit Switch Contact Access Blocked Red Light Illuminated Bollard VIGILO 2250 Common Limit Swith Open Lowered bollard Limi...

Page 11: ...rd to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to lock the hydraulic circuit make sure that the system is supplied with voltage and pulse for the bollard to rise Release spanner 3 One turn anti clockwise to over ride 2 Locate the spanner in the over...

Page 12: ...of an ever increasing process of improvement The CE mark certifies that the operator conforms to the essential requirements of the European Directive art 10 EEC 73 23 in relation to the manufacturer s declaration for the supplied items in compliance with the body of the regulations ISO 9000 UNI EN 29000 Automation in conformity to EN 12453 EN 12445 safety standard Bollard flush with ground level F...

Reviews: