72
Sensor configuration
Sensor position settings
In this section you can insert up to four sensor positions. Each balancing plane
must have at least one sensor position. If you add a new balancing configuration
to the system configuration, a sensor position is automatically added per
balancing plane.
Sensor position
: Enter a name for the sensor here (maximum of 5 characters).
Due to the size of the Detector display this can only be 5 characters long.
BNC connector
: Select the BNC port
used to connect the sensor during the
measurement. If you are measuring with two sensors, you should use both
BNC connectors on the Detector as this accelerates the speed of
measurement.
Angle
: Enter the angle of displacement of the sensor from the zero position in
the direction of shaft rotation. The stator is always used as the reference for the
zero position which points vertically upwards.
Sensor
: Select the sensor used from the sensor database
here.
216
45