73
Trendline 3
Trigger settings
Select trigger sensor
: Select the trigger sensor used from the sensor
here.
Name of trigger position
: Enter a designation for the trigger position. This is
required by the Detector to identify the trigger sensor. Due to the size of the
Detector display, this name can only be five characters long.
Angle of trigger sensor
: Enter the angle of displacement of the trigger sensor
from the zero position in the direction of rotation. The stator is always used as
the reference for the zero position which points vertically upwards.
Select
Positive
or
Negative
to indicate whether the measurement should start
on a positive or negative edge on the trigger sensor. This edge determines the
0° position of the shaft.
Configured angles
In this area the Trendline software provides a graphic representation of the
position of the sensors.
The sensor positions are always counted in the direction of shaft
rotation.
Measuring data
You can view the measured data in this area once a balancing measurement is
complete and the data have been transferred to the Trendline software from the
Detector.
45