(34/35) - Appendix - Installation/Operation - 10iE-20iE - (Soft: 01.xx)
4.3 Error codes
If any message other than the first two fro m the table were to come up, the
equipment should be switche d off and on again until one of the first two are
seen.
After pressing this key to access the counting mode, check the parameters.
If any of the errors shown as (Service De partment) are often repeated, ask
Fagor Automation’s Customer Services Department about this.
If the display of any axis sho ws all its d ots; for example: 1.4.3.6.5.7.2.5. It
means that the axis has been moved too fast (>200 KHz or 60 m/min with 1
µm resolution). This error will be displayed if the alarm activation parameter
for the axis PAR08(1) = 1
To clear the display, press this key.
If the axis value is flashing, this means that one of the travel limits established
by machine parameter has been exceeded. This error will be displayed if the
alarm activation parameter for the axis PAR08(2) = 1
If the DRO does not come on or goes out while runnin g, check that the
voltage and ground outlets are as they should be. If there are OK, disconnect
the feedback connectors one by one. If the dro comes on, it mean s a
feedback failure. If the fau lt persists get in tou ch with Fag or Automation’s
Customer Services Department about it.
Error codes
Error
Description
FAGOR dro
Power outage or turned off with main switch after saving the data.
Error 02
The unit has been turned off without previously pressing [ON/OFF]. It only looses
feedback reading (it resets it to zero and the status of the operating modes, inch,
abs, radius, etc.).
Error 04
Wrong parameter data
Error 05
Wrong internal configuration
Error 06
Errors in data backup memory (Service Dept.)
Error 07
Emergency input active. Press [CLEAR] or cancel the emergency signal.
Error 08
Wrong software memory or the software has been changed.
Error 09
Errors in work memory (Service Dept.)
Error 12
Error while searching a distance-coded reference mark (Io).
Error 31
Internal malfunction (Service Dept.).
Error 32
Internal malfunction (Service Dept.).
Error 99
Internal malfunction (Service Dept.).
. . . . . . . .
Feedback alarm coming from the feedback device (linear or rotary encoder).
1. 4. 3. 6. 5. 7. 2. 5 Feedback speed too high.
EEEEEEEE
Maximum position reading or speed exceeded when searching home.