CHANGING THE DIRECTION OF DOOR OPENING
Remove the cabinet control panel housing by
inserting the tip of the screwdriver into the
securing grooves and levering it until the lugs are
released.
Remove the electronic card and switch off the
circuit power supply.
Remove the upper hinge after first removing the
retaining screw. Grasp the upper door with both
hands and remove it from the refrigerator.
Release the opening regulator on the right door
and place it on the left door by screwing carefully
into the holes drilled into the door.
Remove the control panel casing by inserting the
point of a screwdriver into the retaining grooves
and exerting leverage until the rim is freed.
Unscrew the top hinge, and screw it in place on the
left.
Place the card supply wire and earth wire on the
left-hand side and attach the control unit support.
Position the card supply wire in the grooves on the
hinge and attach the linge with the three screws.
Note: check the card power supply wire output
groove.
12